Literature DB >> 19381610

Arthroscopic removal of the failed silicone radial head prosthesis.

Jun-Gyu Moon1, Richard D Southgate, James S Fitzsimmons, Shawn W O'Driscoll.   

Abstract

Although silicone radial head arthroplasty has been successful in many patients, it has been associated with complications such as fractures of the prosthesis and silicone synovitis. Synovectomy and removal of the failed silicone radial head, with or without reimplantation of a metallic radial head, is indicated in such complications. In an effort to perform minimally invasive surgery, we performed arthroscopic removal of the silicone head combined with synovectomy in a series of such patients. The silicone prostheses were cut into two or three pieces and then removed. After a median follow up of 26 months, all patients reported excellent pain relief and there were no residual loose bodies. Removal of a failed silicone radial head can be successfully performed arthroscopically. This arthroscopic technique has the advantage of being minimally invasive and can be combined with other procedures including capsulectomy, if necessary.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19381610     DOI: 10.1007/s00167-009-0796-y

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  11 in total

1.  Excision or Silastic replacement for comminuted radial head fractures. A long-term follow-up.

Authors:  D V Stoffelen; B J Holdsworth
Journal:  Acta Orthop Belg       Date:  1994       Impact factor: 0.500

2.  Synovial and osseous inflammation in failed silicone-rubber prostheses.

Authors:  M Gordon; P G Bullough
Journal:  J Bone Joint Surg Am       Date:  1982-04       Impact factor: 5.284

3.  Fracture of silastic radial-head prosthesis. Case report.

Authors:  W S Mayhall; F T Tiley; D J Paluska
Journal:  J Bone Joint Surg Am       Date:  1981-03       Impact factor: 5.284

4.  Silastic prosthetic replacement for the radial head.

Authors:  B F Morrey; L Askew; E Y Chao
Journal:  J Bone Joint Surg Am       Date:  1981-03       Impact factor: 5.284

5.  Silastic replacement of the head of the radius in trauma.

Authors:  I Mackay; B Fitzgerald; J H Miller
Journal:  J Bone Joint Surg Br       Date:  1979-11

6.  Arthroscopic management of the arthritic elbow: indications, technique, and results.

Authors:  F H Savoie; P D Nunley; L D Field
Journal:  J Shoulder Elbow Surg       Date:  1999 May-Jun       Impact factor: 3.019

7.  Early failure of silicone radial head implants in the rheumatoid elbow. A complication of silicone radial head implant arthroplasty.

Authors:  E Trepman; F C Ewald
Journal:  J Arthroplasty       Date:  1991-03       Impact factor: 4.757

8.  Inflammatory arthritis after failure of silicone rubber replacement of the radial head.

Authors:  R S Vanderwilde; B F Morrey; M W Melberg; T N Vinh
Journal:  J Bone Joint Surg Br       Date:  1994-01

9.  Silicone rubber replacement of the severely fractured radial head.

Authors:  R M Carn; J Medige; D Curtain; A Koenig
Journal:  Clin Orthop Relat Res       Date:  1986-08       Impact factor: 4.176

10.  Elbow arthroscopy for loose bodies.

Authors:  S W O'Driscoll
Journal:  Orthopedics       Date:  1992-07       Impact factor: 1.390

View more
  1 in total

Review 1.  Longitudinal instability of the forearm.

Authors:  J Phadnis; A C Watts
Journal:  Orthopade       Date:  2016-10       Impact factor: 1.087

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.