Abstract

BACKGROUND: Positron-emission tomography (PET) tracers for myocardial perfusion are commonly labeled with short-lived isotopes that limit their widespread clinical use. 18F-BMS-747158-02 (18F-BMS) is a novel pyridaben derivative that was evaluated for assessment of myocardial perfusion by comparison with 13N-ammonia (13NH3) and with radioactive microspheres in a pig model. METHODS AND
RESULTS: Fourteen pigs injected with 500 MBq of 13NH3 or 100 to 200 MBq of 18F-BMS underwent dynamic PET at rest and during pharmacological stress. In 8 of these pigs, 18F-BMS was injected during stress combined with transient, 2.5-minute constriction of the left anterior descending coronary artery. Radioactive microspheres were coinjected with 18F-BMS. Ratios of myocardial tracer uptake to surrounding tissues were determined, and myocardial blood flow was quantified by compartmental modeling. Both tracers showed high and homogeneous myocardial uptake. Compared with 13NH3, 18F-BMS showed higher activity ratios between myocardium and blood (rest 2.5 versus 4.1; stress 2.1 versus 5.8), liver (rest 1.2 versus 1.8; stress 0.7 versus 2.0), and lungs (rest 2.5 versus 4.2; stress 2.9 versus 6.4). Regional myocardial blood flow assessed with 18F-BMS PET showed good correlation (r=0.88, slope=0.84) and agreement (mean difference -0.10 [25th percentile -0.3, 75th percentile 0.1 mL x min(-1) x g(-1)]) with that measured with radioactive microspheres over a flow range from 0.1 to 3.0 mL x min(-1) x g(-1). The extent of defects induced by left anterior descending coronary artery constriction measured by 18F-BMS and microspheres also correlated closely (r=0.63, slope=1.1).
CONCLUSIONS: 18F-BMS-747158-02 is a very attractive new PET perfusion tracer that allows quantitative assessment of regional myocardial perfusion over a wide flow range. The long half-life of 18F renders this tracer useful for clinical PET/CT applications in the workup of patients with suspected or proven coronary artery disease.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19380625     DOI: 10.1161/CIRCULATIONAHA.108.797761

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  69 in total

Review 1.  PET measurement of adenosine stimulated absolute myocardial blood flow for physiological assessment of the coronary circulation.

Authors:  Henry Gewirtz
Journal:  J Nucl Cardiol       Date:  2012-04       Impact factor: 5.952

Review 2.  Improvement in PET myocardial perfusion image quality and quantification with flurpiridaz F 18.

Authors:  Daniel S Berman; Guido Germano; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2012-02       Impact factor: 5.952

Review 3.  PET: Is myocardial flow quantification a clinical reality?

Authors:  Antti Saraste; Sami Kajander; Chunlei Han; Sergey V Nesterov; Juhani Knuuti
Journal:  J Nucl Cardiol       Date:  2012-10       Impact factor: 5.952

4.  The technetium shortage.

Authors:  Gregory S Thomas; Jamshid Maddahi
Journal:  J Nucl Cardiol       Date:  2010-12       Impact factor: 5.952

5.  Novel F-18-labeled PET myocardial perfusion tracers: bench to bedside.

Authors:  Stephan G Nekolla; Antti Saraste
Journal:  Curr Cardiol Rep       Date:  2011-04       Impact factor: 2.931

6.  Cardiac imaging and safety evaluation of BMS747158, a novel PET myocardial perfusion imaging agent, in chronic myocardial compromised rabbits.

Authors:  Ming Yu; Jody Bozek; Mary Guaraldi; Mikhail Kagan; Michael Azure; Simon P Robinson
Journal:  J Nucl Cardiol       Date:  2010-03-26       Impact factor: 5.952

7.  Advances in quantitative assessment of myocardial blood flow and coronary reserve.

Authors:  Giovanni Lucignani; Alberto Cuocolo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-10       Impact factor: 9.236

Review 8.  Coronary vasomotor function assessed by positron emission tomography.

Authors:  Nagara Tamaki; Keiichiro Yoshinaga; Masanao Naya
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-11-24       Impact factor: 9.236

9.  Will cardiac positron emission tomography ultimately replace SPECT for myocardial perfusion imaging?

Authors:  George A Beller
Journal:  J Nucl Cardiol       Date:  2009 Nov-Dec       Impact factor: 5.952

10.  Myocardial uptake of 7'-(Z)-[(123)I]iodorotenone during vasodilator stress in dogs with critical coronary stenoses.

Authors:  Alexis Broisat; Mirta Ruiz; Norman C Goodman; Stephen M Hanrahan; Bryan W Reutter; Kathleen M Brennan; Mustafa Janabi; Saul Schaefer; Denny D Watson; George A Beller; Henry F VanBrocklin; David K Glover
Journal:  Circ Cardiovasc Imaging       Date:  2011-09-14       Impact factor: 7.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.