Literature DB >> 19379157

Standard on microbiological management of fluids for hemodialysis and related therapies by the Japanese Society for Dialysis Therapy 2008.

Hideki Kawanishi1, Takashi Akiba, Ikuto Masakane, Tadashi Tomo, Michio Mineshima, Tadayuki Kawasaki, Hideki Hirakata, Tadao Akizawa.   

Abstract

The Committee of Scientific Academy of the Japanese Society for Dialysis Therapy (JSDT) proposes a new standard on microbiological management of fluids for hemodialysis and related therapies. This standard is within the scope of the International Organization for Standardization (ISO), which is currently under revision. This standard is to be applied to the central dialysis fluid delivery systems (CDDS), which are widely used in Japan. In this standard, microbiological qualities for dialysis water and dialysis fluids are clearly defined by endotoxin level and bacterial count. The qualities of dialysis fluids were classified into three levels: standard, ultrapure, and online prepared substitution fluid. In addition, the therapeutic application of each dialysis fluid is clarified. Since high-performance dialyzers are frequently used in Japan, the standard recommends that ultrapure dialysis fluid be used for all dialysis modalities at all dialysis facilities. It also recommends that the dialysis equipment safety management committee at each facility should validate the microbiological qualities of online prepared substitution fluid.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19379157     DOI: 10.1111/j.1744-9987.2009.00674.x

Source DB:  PubMed          Journal:  Ther Apher Dial        ISSN: 1744-9979            Impact factor:   1.762


  8 in total

1.  Japanese society for dialysis therapy renal data registry-a window through which we can view the details of Japanese dialysis population.

Authors:  Norio Hanafusa; Shigeru Nakai; Kunitoshi Iseki; Yoshiharu Tsubakihara
Journal:  Kidney Int Suppl (2011)       Date:  2015-06

2.  Dialysis and quality of dialysate in southeast asian developing countries.

Authors:  Tomotaka Naramura; Toru Hyodo; Kenichi Kokubo; Hirokazu Matsubara; Haruki Wakai; Fumitaka Nakajima; Nobuhisa Shibahara; Kazunari Yoshida; Yoshinori Komaru; Hideki Kawanishi; Akio Kawamura; Hideo Hidai; Shingo Takesawa
Journal:  Nephron Extra       Date:  2014-04-23

3.  Changes in Cerebral Oxygenation Associated with Intradialytic Blood Transfusion in Patients with Severe Anemia Undergoing Hemodialysis.

Authors:  Kiyonori Ito; Susumu Ookawara; Yuichiro Ueda; Haruhisa Miyazawa; Masaya Kofuji; Hideyuki Hayasaka; Takayuki Uchida; Katsunori Yanai; Hiroki Ishii; Mitsutoshi Shindo; Taisuke Kitano; Keiji Hirai; Yoshio Kaku; Taro Hoshino; Kaoru Tabei; Yoshiyuki Morishita
Journal:  Nephron Extra       Date:  2017-04-28

4.  Factors associating with oxygenation of lower-limb muscle tissue in hemodialysis patients.

Authors:  Haruhisa Miyazawa; Susumu Ookawara; Kiyonori Ito; Katsunori Yanai; Hiroki Ishii; Taisuke Kitano; Mitsutoshi Shindo; Yuichiro Ueda; Yoshio Kaku; Keiji Hirai; Taro Hoshino; Kaoru Tabei; Yoshiyuki Morishita
Journal:  World J Nephrol       Date:  2016-11-06

5.  Haemodiafiltration-optimal efficiency and safety.

Authors:  Ingrid Ledebo; Peter J Blankestijn
Journal:  NDT Plus       Date:  2009-11-05

6.  High-quality dialysis: a lesson from the Japanese experience: Effects of membrane material on nutritional status and dialysis-related symptoms.

Authors:  Ikuto Masakane
Journal:  NDT Plus       Date:  2010-05

Review 7.  The production of on-line dialysis water for extracorporeal dialysis: proposals for an increased safety upgrade: a viewpoint.

Authors:  Piergiorgio Bolasco
Journal:  J Nephrol       Date:  2019-11-12       Impact factor: 3.902

Review 8.  Current approaches to middle molecule removal: room for innovation.

Authors:  Ikuto Masakane; Kenji Sakurai
Journal:  Nephrol Dial Transplant       Date:  2018-10-01       Impact factor: 5.992

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.