An ultrasonic method for measuring tissue displacement: technical details and validation for measuring myocardial thickening.

C J Hartley1, H Litowitz, R S Rabinovitz, W X Zhu, J E Chelly, L H Michael, R Bolli.   

Abstract

We have developed a method for measuring myocardial thickening from a single ultrasonic transducer attached to the epicardium. Displacement of the underlying myocardial tissue is measured by following the phase of the echoes within a sample volume range-gated across the myocardium. The output is in the form of an analog signal. To verify the accuracy, resolution, and limitations of the system, we derived the equations relating the position of a reflector to the phase of its echo and compared the system output in vitro to a known input using a single moving target and a random distribution of scatterers, and in vivo to that of an ultrasonic transit-time dimension gauge. The results demonstrate that the 10 MHz system can accurately follow the motion of single or multiple targets with a resolution of 0.02 mm. In 25 dogs myocardial thickening measured with the displacement system compared favorably in both waveform and magnitude with thickening measured by the two-crystal transit-time method. Applications for the displacement method include: quantification of regional ventricular function in animal models of cardiovascular diseases, measurement of endocardial to epicardial differences in the deformation of regional myocardium during the cardiac cycle, and evaluation of regional cardiac function in patients during and after corrective cardiac surgery.

Entities:  

Mesh:

Year:  1991        PMID: 1937506     DOI: 10.1109/10.83585

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  4 in total

Review 1.  Quantitative tagged magnetic resonance imaging of the normal human left ventricle.

Authors:  C C Moore; E R McVeigh; E A Zerhouni
Journal:  Top Magn Reson Imaging       Date:  2000-12

Review 2.  Doppler velocity measurements from large and small arteries of mice.

Authors:  Craig J Hartley; Anilkumar K Reddy; Sridhar Madala; Mark L Entman; Lloyd H Michael; George E Taffet
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-05-13       Impact factor: 4.733

3.  Validation of a 3D computational fluid-structure interaction model simulating flow through an elastic aperture.

Authors:  A Quaini; S Canic; R Glowinski; S Igo; C J Hartley; W Zoghbi; S Little
Journal:  J Biomech       Date:  2011-12-03       Impact factor: 2.712

4.  Effects of a Novel Leumedin NPC 15669 on Myocardial Stunning and Preconditioned Infarction Size in Swine.

Authors: 
Journal:  J Thromb Thrombolysis       Date:  1995       Impact factor: 2.300

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.