The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

Ping-Liang Yang1, David T Wong, Shuang-Bo Dai, Hai-Bo Song, Ling Ye, Jin Liu, Bin Liu.   

Abstract

BACKGROUND: There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery.
METHODS: In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients.
RESULTS: Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were <10%. Interobserver and intraobserver reproducibility in left renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min.
CONCLUSION: In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

Entities:  

Mesh:

Year:  2009        PMID: 19372314     DOI: 10.1213/ane.0b013e3181923d2e

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  2 in total

1.  Unexpected co-arctation of aorta detected by transesophageal echocardiography during patent ductus arteriosus ligation.

Authors:  Fei Liu; Ming-chon Hsiung; Haibo Song; Ke Dian; Hong Tang; Jin Liu
Journal:  Front Med       Date:  2013-05-17       Impact factor: 4.592

2.  Feasibility of measuring superior mesenteric artery blood flow during cardiac surgery under hypothermic cardiopulmonary bypass using transesophageal echocardiography: An observational study.

Authors:  Naveen G Singh; P S Nagaraja; Divya Gopal; V Manjunath; K S Nagesh; N Manjunatha; Guru Police Patel; Satish Kumar Mishra
Journal:  Ann Card Anaesth       Date:  2016 Jul-Sep
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.