Numerical evaluation of blood damage in a magnetically levitated heart pump - biomed 2009.

Alexandrina Untaroiu1, Houston G Wood, Paul E Allaire.   

Abstract

The prospect of Ventricular Assist Devices used for long-term support of congestive heart failure patients is directly dependent upon excellent blood compatibility. High fluid stress levels may arise due to high rotational speeds and narrow clearances between the stationary and rotating parts of the pump. Thus, fluid stress may result in damage to red blood cells and activation of platelets, contributing to thrombus formation. Therefore, it is essential to evaluate levels of blood trauma for successful design of a Ventricular Assist Device. Estimating the fluid stress levels that occur in a blood pump during the design phase also provides valuable information for optimization considerations. This study describes the CFD evaluation of blood damage in a magnetically suspended axial pump that occurs due to fluid stress. Using CFD, a blood damage index, reflecting the percentage of damaged red blood cells, was numerically estimated based on the scalar fluid stress values and exposure time to such stresses. A number of particles, with no mass and reactive properties, was injected at the inflow of the computational domain at a time t = 0 and traveled along their corresponding streamlines. A Lagrangian particle tracking technique was employed to obtain the stress history of each particle along its streamline, making it possible to consider the damage history of each particle. Maximum scalar stresses of approximately 430 Pa were estimated to occur along the tip surface of the impeller blades, more precisely at the leading edge of the impeller blades. The maximum time required for the vast majority of particles to pass through the pump was approximately 0.085sec. A small number of particles approximately 5%), which traveled through the narrow gap between the stationary and rotating part of the pump, exited the computational domain in approximately 0.2 sec. The mean value of blood damage index was found to be 0.15% with a maximum value of approximately 0.47%. These values are one order of magnitude lower than the approximated damage indices published in the literature for other Ventricular Assist Devices. The low blood damage index indicates that red blood cells traveling along the streamlines considered are not likely to be ruptured, mainly due to the very small time of exposure to high stress.

Entities:  

Year:  2009        PMID: 19369766

Source DB:  PubMed          Journal:  Biomed Sci Instrum        ISSN: 0067-8856


  1 in total

1.  A novel device for elimination of cancer cells from blood specimens.

Authors:  Agnes Weth; Ilona Krol; Kurt Priesner; Cinzia Donato; Stefan Pirker; Christoph Wolf; Nicola Aceto; Werner Baumgartner
Journal:  Sci Rep       Date:  2020-06-23       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.