Literature DB >> 19367620

Monitoring the film coating unit operation and predicting drug dissolution using terahertz pulsed imaging.

Louise Ho1, Ronny Müller, Keith C Gordon, Peter Kleinebudde, Michael Pepper, Thomas Rades, Yaochun Shen, Philip F Taday, J Axel Zeitler.   

Abstract

Understanding the coating unit operation is imperative to improve product quality and reduce output risks for coated solid dosage forms. Three batches of sustained-release tablets coated with the same process parameters (pan speed, spray rate, etc.) were subjected to terahertz pulsed imaging (TPI) analysis followed by dissolution testing. Mean dissolution times (MDT) from conventional dissolution testing were correlated with terahertz waveforms, which yielded a multivariate, partial least squares regression (PLS) model with an R(2) of 0.92 for the calibration set and 0.91 for the validation set. This two-component, PLS model was built from batch I that was coated in the same environmental conditions (air temperature, humidity, etc.) to that of batch II but at different environmental conditions from batch III. The MDTs of batch II was predicted in a nondestructive manner with the developed PLS model and the accuracy of the predicted values were subsequently validated with conventional dissolution testing and found to be in good agreement. The terahertz PLS model was also shown to be sensitive to changes in the coating conditions, successfully identifying the larger coating variability in batch III. In this study, we demonstrated that TPI in conjunction with PLS analysis could be employed to assist with film coating process understanding and provide predictions on drug dissolution. 2009 Wiley-Liss, Inc. and the American Pharmacists Association

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19367620     DOI: 10.1002/jps.21766

Source DB:  PubMed          Journal:  J Pharm Sci        ISSN: 0022-3549            Impact factor:   3.534


  2 in total

1.  Applying terahertz technology for nondestructive detection of crack initiation in a film-coated layer on a swelling tablet.

Authors:  Wataru Momose; Hiroyuki Yoshino; Yoshifumi Katakawa; Kazunari Yamashita; Keiji Imai; Kazuhiro Sako; Eiji Kato; Akiyoshi Irisawa; Etsuo Yonemochi; Katsuhide Terada
Journal:  Results Pharma Sci       Date:  2012-04-13

Review 2.  Review of Terahertz Pulsed Imaging for Pharmaceutical Film Coating Analysis.

Authors:  Décio Alves-Lima; Jun Song; Xiaoran Li; Alessia Portieri; Yaochun Shen; J Axel Zeitler; Hungyen Lin
Journal:  Sensors (Basel)       Date:  2020-03-06       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.