Literature DB >> 19365799

Simultaneously recorded EEG-fMRI: removal of gradient artifacts by subtraction of head movement related average artifact waveforms.

Limin Sun1, Hermann Hinrichs.   

Abstract

Electroencephalograms (EEGs) recorded simultaneously with functional magnetic resonance imaging (fMRI) are corrupted by large repetitive artifacts generated by the switched MR gradients. Several methods have been proposed to remove these distortions by subtraction of averaged artifact templates from the ongoing EEG. Here, we present a modification of this approach which accounts for head movements to improve the extracted template. Using the fMRI analysis package statistical parametric mapping (SPM; FIL London) the head displacement is determined at each half fMRI-volume. The basic idea is to apply a moving average algorithm for template extraction but to include only epochs that were obtained at the same head position as the artefact to be removed. This approach was derived from phantom EEG measurements demonstrating substantial variations of the artefact waveform in response to movements of the phantom in the MRI magnet. To further reduce the residual noise, we applied a resampling algorithm which aligns the EEG samples in a strict adaptive manner to the fMRI timing. Finally, we propose a new algorithm to suppress residual artifacts such as those occasionally observed in case of brief strong movements, which are not reflected by the movement indicator because of the limited temporal resolution of the fMRI sequence. On the basis of EEG recordings of six subjects these measures combined reduce the residual artefact activity quantified in terms of the spectral power at the gradient repetition rate and its harmonics by roughly 20 to 50% (depending on the amount of movement) predominantly in frequencies beyond 30 Hz.

Mesh:

Substances:

Year:  2009        PMID: 19365799      PMCID: PMC6870712          DOI: 10.1002/hbm.20758

Source DB:  PubMed          Journal:  Hum Brain Mapp        ISSN: 1065-9471            Impact factor:   5.038


  24 in total

1.  Restoration of MR-induced artifacts in simultaneously recorded MR/EEG data.

Authors:  J Sijbers; I Michiels; M Verhoye; J Van Audekerke; A Van der Linden; D Van Dyck
Journal:  Magn Reson Imaging       Date:  1999-11       Impact factor: 2.546

2.  Acquiring simultaneous EEG and functional MRI.

Authors:  R I Goldman; J M Stern; J Engel; M S Cohen
Journal:  Clin Neurophysiol       Date:  2000-11       Impact factor: 3.708

3.  A method for removing imaging artifact from continuous EEG recorded during functional MRI.

Authors:  P J Allen; O Josephs; R Turner
Journal:  Neuroimage       Date:  2000-08       Impact factor: 6.556

4.  Real-time MR artifacts filtering during continuous EEG/fMRI acquisition.

Authors:  G Garreffa; M Carnì; G Gualniera; G B Ricci; L Bozzao; D De Carli; P Morasso; P Pantano; C Colonnese; V Roma; B Maraviglia
Journal:  Magn Reson Imaging       Date:  2003-12       Impact factor: 2.546

5.  Removal of time-varying gradient artifacts from EEG data acquired during continuous fMRI.

Authors:  Michiro Negishi; Mark Abildgaard; Terry Nixon; Robert Todd Constable
Journal:  Clin Neurophysiol       Date:  2004-09       Impact factor: 3.708

6.  Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: removal of the ballistocardiogram artefact.

Authors:  Stefan Debener; Alexander Strobel; Bettina Sorger; Judith Peters; Cornelia Kranczioch; Andreas K Engel; Rainer Goebel
Journal:  Neuroimage       Date:  2006-11-16       Impact factor: 6.556

7.  Artifact removal in co-registered EEG/fMRI by selective average subtraction.

Authors:  S I Gonçalves; P J W Pouwels; J P A Kuijer; R M Heethaar; J C de Munck
Journal:  Clin Neurophysiol       Date:  2007-09-21       Impact factor: 3.708

8.  EEG-correlated fMRI of human alpha activity.

Authors:  H Laufs; A Kleinschmidt; A Beyerle; E Eger; A Salek-Haddadi; C Preibisch; K Krakow
Journal:  Neuroimage       Date:  2003-08       Impact factor: 6.556

9.  Monitoring the patient's EEG during echo planar MRI.

Authors:  J R Ives; S Warach; F Schmitt; R R Edelman; D L Schomer
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1993-12

10.  Electroencephalography during functional echo-planar imaging: detection of epileptic spikes using post-processing methods.

Authors:  A Hoffmann; L Jäger; K J Werhahn; M Jaschke; S Noachtar; M Reiser
Journal:  Magn Reson Med       Date:  2000-11       Impact factor: 4.668

View more
  5 in total

1.  Vibrotactile piezoelectric stimulation system with precise and versatile timing control for somatosensory research.

Authors:  Limin Sun; Yoshio Okada
Journal:  J Neurosci Methods       Date:  2019-02-07       Impact factor: 2.390

2.  Photoelectric artefact from optogenetics and imaging on microelectrodes and bioelectronics: New Challenges and Opportunities.

Authors:  Takashi D Y Kozai; Alberto L Vazquez
Journal:  J Mater Chem B       Date:  2015-07-07       Impact factor: 6.331

3.  Removing Cardiac Artefacts in Magnetoencephalography with Resampled Moving Average Subtraction.

Authors:  Limin Sun; Seppo P Ahlfors; Hermann Hinrichs
Journal:  Brain Topogr       Date:  2016-08-08       Impact factor: 3.020

4.  A new method for analyzing auditory brain-stem response waveforms using a moving-minimum subtraction procedure of digitized analog recordings.

Authors:  Johan Källstrand; Tommy Lewander; Eva Baghdassarian; Sören Nielzén
Journal:  Neuropsychiatr Dis Treat       Date:  2014-06-06       Impact factor: 2.570

5.  Gradient Artefact Correction and Evaluation of the EEG Recorded Simultaneously with fMRI Data Using Optimised Moving-Average.

Authors:  José L Ferreira; Yan Wu; René M H Besseling; Rolf Lamerichs; Ronald M Aarts
Journal:  J Med Eng       Date:  2016-06-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.