Literature DB >> 19365103

Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration.

Gregor Brüllmann1, Karsten Fritsch, Robert Thurnheer, Konrad E Bloch.   

Abstract

BACKGROUND: Portable respiratory inductive plethysmography (RIP) is promising for noninvasive monitoring of breathing patterns in unrestrained subjects. However, its use has been hampered by requiring recalibration after changes in body position.
OBJECTIVES: To facilitate RIP application in unrestrained subjects, we developed a technique for adjustment of RIP calibration using position sensor feedback.
METHODS: Five healthy subjects and 12 patients with lung disease were monitored by portable RIP with sensors incorporated within a body garment. Unrestrained individuals were studied during 40-60 min while supine, sitting and upright/walking. Position was changed repeatedly every 5-10 min. Initial qualitative diagnostic calibration followed by volume scaling in absolute units during 20 breaths in different positions by flow meter provided position-specific volume-motion coefficients for RIP. These were applied during subsequent monitoring in corresponding positions according to feedback from 4 accelerometers placed at the chest and thigh. Accuracy of RIP was evaluated by face mask pneumotachography.
RESULTS: Position sensor feedback allowed accurate adjustment of RIP calibration during repeated position changes in subjects and patients as reflected in a minor mean difference (bias) in breath-by-breath tidal volumes estimated by RIP and flow meter of 0.02 liters (not significant) and limits of agreement (+/-2 SD) of +/-19% (2,917 comparisons). An average of 10 breaths improved precision of RIP (limits of agreement +/-14%).
CONCLUSIONS: RIP calibration incorporating position sensor feedback greatly enhances the application of RIP as a valuable, unobtrusive tool to investigate respiratory physiology and ventilatory limitation in unrestrained healthy subjects and patients with lung disease during everyday activities including position changes. Copyright 2009 S. Karger AG, Basel.

Entities:  

Mesh:

Year:  2009        PMID: 19365103     DOI: 10.1159/000212117

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  9 in total

1.  Time-varying signal analysis to detect high-altitude periodic breathing in climbers ascending to extreme altitude.

Authors:  A Garde; B F Giraldo; R Jané; T D Latshang; A J Turk; T Hess; M M Bosch; D Barthelmes; T M Merz; J Pichler Hefti; O D Schoch; K E Bloch
Journal:  Med Biol Eng Comput       Date:  2015-03-31       Impact factor: 2.602

2.  Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate.

Authors:  Pragya Sharma; Xiaonan Hui; Jianlin Zhou; Thomas B Conroy; Edwin C Kan
Journal:  NPJ Digit Med       Date:  2020-07-28

3.  Assessment of an alternative calibration technique to record breathing pattern and its variability with respiratory inductive plethysmography.

Authors:  Wai Leung Ambrose Lo; Dong Feng Huang
Journal:  J Clin Monit Comput       Date:  2016-06-11       Impact factor: 2.502

4.  Validation of Respiratory Inductance Plethysmography for Measuring Tidal Volume in Swine.

Authors:  Zhenbo Su; Jun Oto; Jingwen Wang; William R Kimball; Christopher T Chenelle; Robert M Kacmarek; David R King; Yandong Jiang; Michael J Duggan
Journal:  Comp Med       Date:  2015-06       Impact factor: 0.982

5.  Respiratory monitoring by porphyrin modified quartz crystal microbalance sensors.

Authors:  Roman Selyanchyn; Serhiy Korposh; Shunichi Wakamatsu; Seung-Woo Lee
Journal:  Sensors (Basel)       Date:  2011-01-20       Impact factor: 3.576

6.  Investigating Stroke Effects on Respiratory Parameters Using a Wearable Device: A Pilot Study on Hemiplegic Patients.

Authors:  Joshua Di Tocco; Daniela Lo Presti; Martina Zaltieri; Marco Bravi; Michelangelo Morrone; Silvia Sterzi; Emiliano Schena; Carlo Massaroni
Journal:  Sensors (Basel)       Date:  2022-09-05       Impact factor: 3.847

7.  Objective Scoring of Physiologically Induced Dyspnea by Non-Invasive RF Sensors.

Authors:  Zijing Zhang; Pragya Sharma; Thomas Conroy; Veerawat Phongtankuel; Edwin Chihchuan Kan
Journal:  IEEE Trans Biomed Eng       Date:  2021-12-23       Impact factor: 4.538

8.  Development of a respiratory inductive plethysmography module supporting multiple sensors for wearable systems.

Authors:  Zhengbo Zhang; Jiewen Zheng; Hao Wu; Weidong Wang; Buqing Wang; Hongyun Liu
Journal:  Sensors (Basel)       Date:  2012-09-27       Impact factor: 3.576

9.  Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate.

Authors:  Pragya Sharma; Xiaonan Hui; Jianlin Zhou; Thomas B Conroy; Edwin C Kan
Journal:  NPJ Digit Med       Date:  2020-07-28
  9 in total