Literature DB >> 19364655

Occipitocervical fusion using a hook and rod system between cervical levels C2 and C3.

Takao Motosuneya1, Shigeru Hirabayashi, Hironobu Yamada, Hiroya Sakai.   

Abstract

We aimed to evaluate the clinical utility and safety of the hook and rod method for occipitocervical fusion. Eleven consecutive patients (3 males, 8 females; 50-78 years old, average 63.8 years; 16-77 months follow-up, average 33.7 months) with unstable lesions at the craniocervical junction who underwent occipitocervical fusion using a hook and rod system were examined. A Compact Cotrel-Dubousset cervical system (Sofamor-Danek, Memphis TN, USA) was used in all patients. The claw mechanism was applied bilaterally between the hook on the C2 lamina and the hook on the C3 inferior articular process. No complications occurred during surgery. Solid bony fusion was obtained in all patients and no patient became clinically worse postoperatively. Occipitocervical fusion using a hook and rod system is a useful procedure that allows decompression of the spinal cord and secure spinal fusion at multiple levels simultaneously.

Entities:  

Mesh:

Year:  2009        PMID: 19364655     DOI: 10.1016/j.jocn.2008.10.006

Source DB:  PubMed          Journal:  J Clin Neurosci        ISSN: 0967-5868            Impact factor:   1.961


  4 in total

1.  The role of imaging in the pre- and postoperative evaluation of posterior occipito-cervical fusion.

Authors:  A Leone; A Costantini; M Visocchi; A Vestito; P Colelli; N Magarelli; C Colosimo; L Bonomo
Journal:  Radiol Med       Date:  2011-11-17       Impact factor: 3.469

2.  Surgical outcomes and complications after occipito-cervical fusion using the screw-rod system in craniocervical instability.

Authors:  Sung Ho Choi; Sang Gu Lee; Chan Woo Park; Woo Kyung Kim; Chan Jong Yoo; Seong Son
Journal:  J Korean Neurosurg Soc       Date:  2013-04-30

3.  Posterior occipito cervical decompression with fixation and fusion in Cranio vertebral junction compression.

Authors:  Lal Rehman; Iram Bokhari; Ali Afzal; Shakeel Ahmad
Journal:  Pak J Med Sci       Date:  2017 Sep-Oct       Impact factor: 1.088

4.  Surgical, clinical, and radiological outcomes of occipitocervical fusion using the plate-screw-rod system with allograft in craniocervical instability.

Authors:  Mihir Upadhyaya; Sanyam Jain; Neilakuo Kire; Zahir Merchant; Vishal Kundnani; Ankit Patel
Journal:  J Craniovertebr Junction Spine       Date:  2020-01-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.