Literature DB >> 19363448

Carotid computed tomography angiography with automated bone suppression: a comparative study between dual energy and bone subtraction techniques.

Michael M Lell1, Manuel Kramer, Ernst Klotz, Pablo Villablanca, Stefan G Ruehm.   

Abstract

OBJECTIVES: Computed tomography angiography (CTA) is a well-accepted imaging modality to evaluate the vessels of the head and neck. To improve the assessment of vessels at or within the skull base, different techniques to suppress bone in the final CTA image have been developed. We sought to compare the performance of fully automated bone removal based on dual energy (DE) and image registration (bone subtraction CTA [BSCTA]) for the supraaortic vasculature.
MATERIALS AND METHODS: Twenty-seven patients underwent carotid CTA on a dual source CT system. Two scans were performed, one before and one after contrast agent injection in DE mode (simultaneous acquisition of 80 and 140 kV scans). For each patient, data sets were reconstructed for post processing with DE and BSCTA. Two examiners evaluated overall bone suppression and image quality regarding integrity of the vessel lumen of different vessel segments (n = 19) with a 5-point scale (1 = poor, 5 = excellent), CTA source data served as the reference. Wilcoxon signed rank test was used to determine differences between the techniques. Cohen's kappa was used to determine interobserver agreement.
RESULTS: Both bone suppression techniques could be applied successfully in 25 patients with high overall image quality. Two patients were excluded from the evaluation for technical reasons. Interobserver agreement was excellent (kappa = 0.85). Mean score of all vessel segments for overall bone removal was 4.45 +/- 0.76 for DE and 4.33 +/- 1.02 for BSCTA; DE performed better in the vessel segment of the neck (external carotid artery, common carotid artery, V1 to V3 segment of the vertebral artery, subclavian artery), whereas BSCTA was superior in the cranial vessels (C3-C6 segment of the internal carotid artery, ophthalmic artery). Vessel integrity was superior with BSCTA, the mean score of all vessel segments for overall vessel integrity was 3.97 +/- 1.47 for DE and 4.49 +/- 0.98 for BSCTA, the subclavian artery was most frequently truncated using DE post processing (mean score: 1.44 +/- 1.2).
CONCLUSIONS: Both techniques provided bone suppression in a fully automated way. DE provided more complete bone suppression in the neck, but at the cost of inferior vessel integrity, especially at the thoracic inlet. BSCTA showed excellent results for vessel integrity and was superior to DE in most of the vessels in or at the skull base.

Entities:  

Mesh:

Year:  2009        PMID: 19363448     DOI: 10.1097/RLI.0b013e31819e8ad9

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  7 in total

Review 1.  Clinical applications of dual-energy CT in head and neck imaging.

Authors:  Daniel Thomas Ginat; Michael Mayich; Laleh Daftari-Besheli; Rajiv Gupta
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-12-04       Impact factor: 2.503

2.  Improved arterial visualization in cerebral CT perfusion-derived arteriograms compared with standard CT angiography: a visual assessment study.

Authors:  A M Mendrik; E P A Vonken; G A P de Kort; B van Ginneken; E J Smit; M A Viergever; M Prokop
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-24       Impact factor: 3.825

3.  Detectability of urinary stones on virtual nonenhanced images generated at pyelographic-phase dual-energy CT.

Authors:  Naoki Takahashi; Terri J Vrtiska; Akira Kawashima; Robert P Hartman; Andrew N Primak; Joel G Fletcher; Cynthia H McCollough
Journal:  Radiology       Date:  2010-07       Impact factor: 11.105

4.  Dual- and multi-energy CT: approach to functional imaging.

Authors:  Juergen Fornaro; Sebastian Leschka; Dennis Hibbeln; Anthony Butler; Nigel Anderson; Gregor Pache; Hans Scheffel; Simon Wildermuth; Hatem Alkadhi; Paul Stolzmann
Journal:  Insights Imaging       Date:  2011-01-19

5.  Dual-energy computed tomography angiography: virtual calcified plaque subtraction in a vascular phantom.

Authors:  Kwang Nam Jin; Jin Wook Chung; Eun-Ah Park; Whal Lee
Journal:  Acta Radiol Open       Date:  2017-07-12

6.  128-slice acceletated-pitch dual energy CT angiography of the head and neck: comparison of different low contrast medium volumes.

Authors:  Yu Chen; Huadan Xue; Zheng-yu Jin; Jie Zhang; Hao Sun; Xuan Wang; Zhu-hua Zhang; Da-ming Zhang; Guang-ming Lu; Zhao-qi Zhang; U Joseph Schoepf; Andreas M Bucher; Christopher D Wolla; Yun Wang
Journal:  PLoS One       Date:  2013-11-19       Impact factor: 3.240

7.  Quantitative benchmarking of iodine imaging for two CT spectral imaging technologies: a phantom study.

Authors:  Vanja Harsaker; Kristin Jensen; Hilde Kjernlie Andersen; Anne Catrine Martinsen
Journal:  Eur Radiol Exp       Date:  2021-06-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.