Literature DB >> 19363024

Tissue Doppler velocity is superior to strain imaging in predicting long-term cardiovascular events after cardiac resynchronisation therapy.

Q Zhang1, R J van Bommel, J W-H Fung, J Y-S Chan, G B Bleeker, C Ypenburg, G Yip, Y-J Liang, M J Schalij, J J Bax, C-M Yu.   

Abstract

OBJECTIVE: To examine the predictive value of systolic dyssynchrony measured by tissue Doppler velocity versus tissue Doppler strain imaging on long-term outcome after cardiac resynchronisation therapy (CRT).
DESIGN: Cohort study.
SETTING: Two university hospitals. PATIENTS: Two hundred and thirty-nine patients (65 (SD 12) years, 76% males) who underwent CRT.
INTERVENTIONS: Baseline echocardiography with tissue Doppler imaging (TDI) and clinical follow-up for 37 (20) months. MAIN OUTCOME MEASURES: The time to peak systolic velocity during ejection phase (Ts) and the time to peak systolic strain (T(epsilon)) were assessed for dyssynchrony, that is the maximal delay in Ts and the maximal delay in T(epsilon) among the four left ventricular basal segments. Occurrence of cardiovascular endpoints between patients with and without dyssynchrony was compared by Kaplan-Meier curves, followed by Cox regression analysis for potential predictor(s).
RESULTS: There were 78 (33%) deaths, with cardiovascular causes in 64 (27%) patients, while 136 (57%) patients were hospitalised for cardiovascular events, including decompensated heart failure in 87 (36%) patients. Patients with the maximal delay in Ts of > or =65 ms showed a lower event rate for cardiovascular mortality (19% vs 38%, logrank chi2 = 7.803, p = 0.005) and other prognostic endpoints. In Cox regression analysis, the maximal delay in Ts (hazard ratio (HR) 0.463, 95% CI 0.270 to 0.792, p = 0.005) and ischaemic aetiology (HR 2.716, 95% CI 1.505 to 4.901, p = 0.001) were independent predictors of cardiovascular mortality. In contrast, the maximal delay in T(epsilon) of > or =80 ms failed to predict any cardiovascular event.
CONCLUSIONS: Echocardiographic evidence of prepacing systolic dyssynchrony measured by TDI velocity, but not TDI strain, predicted lower long-term cardiovascular events after CRT.

Entities:  

Mesh:

Year:  2009        PMID: 19363024     DOI: 10.1136/hrt.2008.161653

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  5 in total

Review 1.  Echocardiography, dyssynchrony, and the response to cardiac resynchronization therapy.

Authors:  Cheuk-Man Yu; John E Sanderson; John Gorcsan
Journal:  Eur Heart J       Date:  2010-08-13       Impact factor: 29.983

Review 2.  Introduction to indexes for cardiac resynchronization therapy (CRT) indication.

Authors: 
Journal:  J Med Ultrason (2001)       Date:  2014-04       Impact factor: 1.314

3.  Clinical implication of mechanical dyssynchrony in heart failure.

Authors:  Qing Zhang; Cheuk-Man Yu
Journal:  J Cardiovasc Ultrasound       Date:  2012-09-21

4.  Almanac 2011: Cardiac Arrhythmias and Pacing. The National Society Journals Present Selected Research that has Driven Recent Advances in Clinical Cardiology.

Authors:  Reginald Liew
Journal:  Mater Sociomed       Date:  2011

5.  Increased myocardial dysfunction, dyssynchrony, and epicardial fat across the lifespan in healthy males.

Authors:  Edward Crendal; Fred Dutheil; Geraldine Naughton; Tracey McDonald; Philippe Obert
Journal:  BMC Cardiovasc Disord       Date:  2014-08-03       Impact factor: 2.298

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.