Literature DB >> 19361743

Microsensor technology to help monitor removable appliance wear.

Marc Bernard Ackerman1, Morgan Stuart McRae, William H Longley.   

Abstract

Retention is routinely prescribed after orthodontic treatment to prevent relapse. Orthodontists often notice a discrepancy between what a patient reports about retainer wear and what a clinical examination shows. In these cases, is the patient misreporting wear, or is the retainer at fault? Scientific Compliance (Atlanta, Ga) has invented, patented, and produced the Smart Retainer environmental microsensor that can be easily incorporated into many types of removable orthodontic appliances to monitor compliance. The technology behind the Smart Retainer environmental microsensor is possible because of recent reductions in electronic component sizes and power requirements. A proprietary USB-powered Smart Reader uses wireless technology to download information about actual usage from the Smart Retainer. The information is decrypted and analyzed, and can be shown to the patient in easy-to-understand charts. The orthodontist can use this information to discuss actual retainer usage vs prescribed retainer usage with the patient or parent and make data-driven recommendations about future retention.

Entities:  

Mesh:

Year:  2009        PMID: 19361743     DOI: 10.1016/j.ajodo.2008.06.021

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  11 in total

1.  Applicative characteristics of new microelectronic sensors Smart Retainer® and TheraMon® for measuring wear time.

Authors:  Timm Cornelius Schott; Gernot Göz
Journal:  J Orofac Orthop       Date:  2010-10-21       Impact factor: 1.938

2.  Performance of clear vacuum-formed thermoplastic retainers depending on retention protocol: a systematic review.

Authors:  Eleftherios G Kaklamanos; Maria Kourakou; Dimitrios Kloukos; Ioannis Doulis; Smaragda Kavvadia
Journal:  Odontology       Date:  2016-06-06       Impact factor: 2.634

3.  Young patients' attitudes toward removable appliance wear times, wear-time instructions and electronic wear-time measurements--results of a questionnaire study.

Authors:  Timm Cornelius Schott; Gernot Göz
Journal:  J Orofac Orthop       Date:  2010-04-01       Impact factor: 1.938

4.  Removable plate treatment of anterior forced crossbite: Effectiveness, efficiency, and potential outcome predictors.

Authors:  Niko C Bock; Heidi Klewitz; Helge Hudel; Sabine Ruf
Journal:  J Orofac Orthop       Date:  2015-07       Impact factor: 1.938

5.  Questionnaire study of electronic wear-time tracking as experienced by patients and parents during treatment with removable orthodontic appliances.

Authors:  T C Schott; S Schrey; J Walter; B A Glasl; B Ludwig
Journal:  J Orofac Orthop       Date:  2013-05-08       Impact factor: 1.938

6.  Objective assessment of patient compliance with removable orthodontic appliances: a cross-sectional cohort study.

Authors:  George Tsomos; Björn Ludwig; Johannes Grossen; Pawel Pazera; Nikolaos Gkantidis
Journal:  Angle Orthod       Date:  2013-07-08       Impact factor: 2.079

7.  Determining the performance of a temperature sensor embedded into a mouthguard.

Authors:  Leonardo de Almeida E Bueno; William Milnthorpe; Jeroen H M Bergmann
Journal:  BDJ Open       Date:  2022-08-01

8.  Effects of wear time recording on the patient's compliance.

Authors:  Alexander Pauls; Manuel Nienkemper; Agamemnon Panayotidis; Benedict Wilmes; Dieter Drescher
Journal:  Angle Orthod       Date:  2013-04-25       Impact factor: 2.079

Review 9.  Oral Appliances in Obstructive Sleep Apnea.

Authors:  Marijke Dieltjens; Olivier Vanderveken
Journal:  Healthcare (Basel)       Date:  2019-11-08

10.  Remote digital monitoring during the retention phase of orthodontic treatment: A prospective feasibility study.

Authors:  Linda Sangalli; Fabio Savoldi; Domenico Dalessandri; Luca Visconti; Francesca Massetti; Stefano Bonetti
Journal:  Korean J Orthod       Date:  2022-03-25       Impact factor: 1.372

View more