Literature DB >> 19361737

Bond failure rates for V-loop vs straight wire lingual retainers.

Krista D Lee1, Christine M Mills.   

Abstract

INTRODUCTION: The V-loop bonded lingual retainer is an innovative design that allows the patient to floss with ease, a significant advantage over the conventional straight wire design for interproximal plaque control. The aim of this retrospective study was to compare the efficacy of straight wire and V-loop fixed retainers with respect to detachment rate when used to stabilize maxillary or mandibular anterior teeth after orthodontic treatment.
METHODS: Fixed, customized retainers were placed in 300 patients and followed for 6 months. The conventional retainer system was a .0175-in stainless steel multi-stranded wire placed as a straight, bonded lingual retainer. The newer system was a .016-in stainless steel black Australian wire placed in a V-loop design.
RESULTS: The detachment rates were 14.3% for the V-loop design and 12.4% for the straight wire retainer. The difference was not statistically significant.
CONCLUSIONS: The V-loop retainer system addresses cleanability and physiologic adaptability, both critical for the clinical success of bonded lingual retainers used for long-term retention. The interdental wire span of the V-loop design allows easier access for flossing and sufficient flexibility for independent tooth movement in the periodontal space. Patient acceptance of the V-loop bonded lingual retainer was excellent, and most patients in this study found the retainer comfortable and easy to floss.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19361737     DOI: 10.1016/j.ajodo.2007.04.037

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  3 in total

Review 1.  What causes failure of fixed orthodontic retention? - systematic review and meta-analysis of clinical studies.

Authors:  Maciej Jedliński; Katarzyna Grocholewicz; Marta Mazur; Joanna Janiszewska-Olszowska
Journal:  Head Face Med       Date:  2021-07-24       Impact factor: 2.151

2.  Fatigue resistance, debonding force, and failure type of fiber-reinforced composite, polyethylene ribbon-reinforced, and braided stainless steel wire lingual retainers in vitro.

Authors:  Dave Lie Sam Foek; Enver Yetkiner; Mutlu Ozcan
Journal:  Korean J Orthod       Date:  2013-08-22       Impact factor: 1.372

3.  Effectiveness of Invisalign® aligners in the treatment of severe gingival recession: A case report.

Authors:  Marcio Antonio de Figueiredo; Fábio Lourenço Romano; Murilo Fernando Neuppmann Feres; Maria Bernadete Sasso Stuani; Ana Carla Raphaelli Nahás-Scocate; Mírian Aiko Nakane Matsumoto
Journal:  Korean J Orthod       Date:  2021-07-25       Impact factor: 1.372

  3 in total