Literature DB >> 19361594

Serial intravascular ultrasound analysis of peri-stent remodeling and proximal and distal edge effects after sirolimus-eluting or paclitaxel-eluting stent implantation in patients with diabetes mellitus.

Lisette Okkels Jensen1, Michael Maeng, Gary S Mintz, Evald Hoej Christiansen, Knud Noerregaard Hansen, Anders Galloe, Henning Kelbaek, Jens Flensted Lassen, Leif Thuesen, Per Thayssen.   

Abstract

Patients with diabetes have an increased risk of in-stent restenosis after coronary stent implantation. Serial intravascular ultrasound was used to study chronic arterial responses and edge effects after implantation of Cypher (Cordis, Johnson & Johnson, Miami Lakes, Florida) or Taxus (Boston Scientific, Maple Grove, Minnesota) stents in diabetic patients. Seventy-four diabetic patients were randomly assigned to Cypher or Taxus stent implantation. Intravascular ultrasound of 5-mm long segments immediately proximal and distal to the stent was performed after the procedure and at the 8-month follow-up. The increase in peri-stent external elastic membrane (EEM) volume was more pronounced in the Taxus group (292.4 +/- 132.6 to 309.5 +/- 146.8 mm(3)) than in the Cypher group (274.4 +/- 137.2 to 275.4 +/- 140.1 mm(3); p = 0.005). Peri-stent plaque volume increased in the Taxus group (152.5 +/- 73.7 to 166.1 +/- 85.1 mm(3)), but was unchanged in the Cypher group (153.5 +/- 75.5 to 151.5 +/- 75.8 mm(3); p = 0.002). In proximal and distal reference segments, mean lumen area decreased within the entire 5-mm edge segment (proximal and distal) because of plaque progression (distal, 5.5 +/- 3.6 to 5.8 +/- 3.7 mm(2); p = 0.097; proximal, 8.1 +/- 2.7 to 8.7 +/- 2.9 mm(2); p = 0.006) without remodeling (change in EEM) in the Taxus group. Conversely, there were no significant changes in reference-segment EEM or plaque areas in the Cypher group. In conclusion, in diabetic patients, Taxus stent implantation was associated with increased (1) peri-stent EEM volume and peri-stent plaque, and (2) stent edge plaque progression accompanied by lumen reduction without remodeling. These findings were not seen in Cypher stents.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19361594     DOI: 10.1016/j.amjcard.2008.12.035

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  2 in total

Review 1.  Dye-Staining Angioscopy for Coronary Artery Disease.

Authors:  Yasumi Uchida; Yasuto Uchida
Journal:  Curr Cardiovasc Imaging Rep       Date:  2015

Review 2.  The role of glucose lowering agents on restenosis after percutaneous coronary intervention in patients with diabetes mellitus.

Authors:  Chris P H Lexis; Braim M Rahel; Joan G Meeder; Felix Zijlstra; Iwan C C van der Horst
Journal:  Cardiovasc Diabetol       Date:  2009-07-28       Impact factor: 9.951

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.