Literature DB >> 19359533

Ultraperformance liquid chromatography-tandem mass spectrometry assay for iohexol in human serum.

Thomas M Annesley1, Larry T Clayton.   

Abstract

BACKGROUND: Iohexol is an iodinated contrast dye that has been shown to be useful in the estimation of glomerular filtration rate (GFR) in patients with suspected renal insufficiency. We developed and validated an ultraperformance liquid chromatography (UPLC)-triple quadrupole mass spectrometry (MS/MS) assay for quantifying iohexol in human serum.
METHODS: Sample preparation involved dilution of 50 microL serum with 400 microL water, followed by protein precipitation with zinc sulfate and methanol containing the structural analog ioversol as the internal standard. After 1:20 dilution of the supernatant with water, 5 microL was injected into the UPLC-MS/MS system. Chromatography was performed using a Waters Oasis HLB 5-microm particle size, 2.1 x 20 mm column maintained at 50 degrees C. We used a 1-step acetonitrile/0.1% formic acid gradient to elute the compounds of interest at a common retention time of 0.96 min. The multiple reaction monitoring transitions used for integration and quantification were m/z 821.7-->803.7 for iohexol and m/z 807.9-->589.0 for ioversol in the electrospray positive ionization mode.
RESULTS: The assay was linear from 2.5 mg/L (lower limit of quantification) to 1500 mg/L iohexol, with a mean extraction efficiency of >99%. Recovery of nominal target concentrations was 99%-102%. Interassay imprecision ranged from 7.9% at a concentration of 2.5 mg/L to 4.1% at 1000 mg/L. Ion suppression studies showed no matrix effects on the ionization of the 2 compounds.
CONCLUSIONS: This rapid UPLC-MS/MS method can be successfully used for quantifying iohexol in human serum.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19359533     DOI: 10.1373/clinchem.2008.121533

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  4 in total

1.  Development of a liquid chromatography tandem mass spectrometry method for the simultaneous determination of zearalenone, deoxynivalenol and their metabolites in pig serum.

Authors:  Ulrike Brezina; Hana Valenta; Inga Rempe; Susanne Kersten; Hans-Ulrich Humpf; Sven Dänicke
Journal:  Mycotoxin Res       Date:  2014-06-13       Impact factor: 3.833

2.  Quantitation of iohexol, a glomerular filtration marker, in human plasma by LC-MS/MS.

Authors:  Julianne L Holleran; Robert A Parise; Jianxia Guo; Brian F Kiesel; Sarah E Taylor; S Percy Ivy; Edward Chu; Jan H Beumer
Journal:  J Pharm Biomed Anal       Date:  2020-07-07       Impact factor: 3.935

3.  Validation of a routine two-sample iohexol plasma clearance assessment of GFR and an evaluation of common endogenous markers in a rat model of CKD.

Authors:  Mandy E Turner; Kimberly J Laverty; Paul S Jeronimo; Martin Kaufmann; Glenville Jones; Christine A White; Rachel M Holden; Michael A Adams
Journal:  Physiol Rep       Date:  2017-05

4.  Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?

Authors:  Pierre Delanaye; Natalie Ebert; Toralf Melsom; Flavio Gaspari; Christophe Mariat; Etienne Cavalier; Jonas Björk; Anders Christensson; Ulf Nyman; Esteban Porrini; Giuseppe Remuzzi; Piero Ruggenenti; Elke Schaeffner; Inga Soveri; Gunnar Sterner; Bjørn Odvar Eriksen; Sten-Erik Bäck
Journal:  Clin Kidney J       Date:  2016-08-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.