Literature DB >> 19356918

A stable and selective electrochemical biosensor for the liver enzyme alanine aminotransferase (ALT).

Mamun Jamal1, Oliver Worsfold, Timothy McCormac, Eithne Dempsey.   

Abstract

An electrochemical method to determine alanine aminotransferase (ALT) activity over its normal and elevated physiological range was developed based upon detection of L-glutamate at a glutamate oxidase-modified platinum electrode. Measurements were carried out in the presence of ALT co-substrates L-alanine and alpha-ketoglutarate and current response from either the oxidation of hydrogen peroxide or the re-oxidation of the mediator ferrocene carboxylic acid was employed. The enzyme electrode was tested over a 6-month period and found to retain 79% of its original activity towards ALT detection with >200 measurements performed over this time. Signals associated with interfering electroactive species (ascorbic acid and uric acid) were eliminated using background subtraction at a denatured glutamate oxidase enzyme electrode. The sensitivity of the device was found to be 0.845 nA U(-1) L ALT with t(90)=180 s, linear range 10-1000 U L(-1) and LOD of 3.29 U L(-1) using amperometry at E(app)=0.4 V vs. Ag/AgCl at 308 K (35 degrees C).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19356918     DOI: 10.1016/j.bios.2009.02.032

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2010-06-15       Impact factor: 6.986

2.  Determination of alanine aminotransferase with an electrochemical nano ir-C biosensor for the screening of liver diseases.

Authors:  Chang-Jung Hsueh; Joanne H Wang; Liming Dai; Chung-Chiun Liu
Journal:  Biosensors (Basel)       Date:  2011-07-12

3.  A Micro-Platinum Wire Biosensor for Fast and Selective Detection of Alanine Aminotransferase.

Authors:  Tran Nguyen Thanh Thuy; Tina T-C Tseng
Journal:  Sensors (Basel)       Date:  2016-05-26       Impact factor: 3.576

Review 4.  Disease-Related Detection with Electrochemical Biosensors: A Review.

Authors:  Ying Huang; Jin Xu; Junjie Liu; Xiangyang Wang; Bin Chen
Journal:  Sensors (Basel)       Date:  2017-10-17       Impact factor: 3.576

5.  Long-Term Stability of a Cellulose-Based Glucose Oxidase Membrane.

Authors:  Soichi Yabuki; Miho Iwamoto; Yoshiki Hirata
Journal:  Materials (Basel)       Date:  2014-01-28       Impact factor: 3.623

6.  An Electrochemical Evaluation of Novel Ferrocene Derivatives for Glutamate and Liver Biomarker Biosensing.

Authors:  Geok Hong Soon; Mary Deasy; Eithne Dempsey
Journal:  Biosensors (Basel)       Date:  2021-07-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.