Literature DB >> 19353344

Three-dimensional double-echo steady-state (3D-DESS) magnetic resonance imaging of the knee: contrast optimization by adjusting flip angle.

S Moriya1, Y Miki, T Yokobayashi, M Ishikawa.   

Abstract

BACKGROUND: The three-dimensional double-echo steady-state (3D-DESS) sequence is being used to investigate sequence parameters for the assessment of knee cartilage by magnetic resonance imaging (MRI). With the flip angle (FA) values that are commonly used, contrast between cartilage and synovial fluid may be too low to delineate minor lesions of the cartilage surface.
PURPOSE: To investigate the value of FA maximizing contrast between cartilage and synovial fluid using the 3D-DESS sequence.
MATERIAL AND METHODS: In 10 healthy volunteers (five men, five women; age range 23-48 years), 3D-DESS imaging was performed to capture median sagittal sections of the knee by adjusting FA from 10 degrees to 90 degrees. Cartilage-synovial fluid contrast-to-noise ratio (CNR) was measured to determine the value of FA maximizing CNR. Water-excitation pulse was used to suppress fat signals. MRI was performed at 1.0 T using a circular polarization flex coil.
RESULTS: Cartilage-synovial fluid CNR was highest with 90 degrees FA, yielding images with good contrast between cartilage and synovial fluid.
CONCLUSION: Simply by increasing FA to 90 degrees in 3D-DESS imaging, the contrast between cartilage and synovial fluid increased substantially. Subtle cartilage lesions may thus be detectable using 3D-DESS sequences.

Entities:  

Mesh:

Year:  2009        PMID: 19353344     DOI: 10.1080/02841850902849444

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  6 in total

1.  Advanced MRI of articular cartilage.

Authors:  Hillary J Braun; Garry E Gold
Journal:  Imaging Med       Date:  2011-10

Review 2.  Understanding Magnetic Resonance Imaging of Knee Cartilage Repair: A Focus on Clinical Relevance.

Authors:  Daichi Hayashi; Xinning Li; Akira M Murakami; Frank W Roemer; Siegfried Trattnig; Ali Guermazi
Journal:  Cartilage       Date:  2017-06-05       Impact factor: 4.634

Review 3.  Articular cartilage in the knee: current MR imaging techniques and applications in clinical practice and research.

Authors:  Michel D Crema; Frank W Roemer; Monica D Marra; Deborah Burstein; Garry E Gold; Felix Eckstein; Thomas Baum; Timothy J Mosher; John A Carrino; Ali Guermazi
Journal:  Radiographics       Date:  2011 Jan-Feb       Impact factor: 5.333

4.  Utilizing shared information between gradient-spoiled and RF-spoiled steady-state MRI signals.

Authors:  Bragi Sveinsson; Garry E Gold; Brian A Hargreaves; Daehyun Yoon
Journal:  Phys Med Biol       Date:  2021-01-14       Impact factor: 3.609

5.  Ultrashort echo time Cones double echo steady state (UTE-Cones-DESS) for rapid morphological imaging of short T2 tissues.

Authors:  Hyungseok Jang; Yajun Ma; Michael Carl; Saeed Jerban; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2021-03-23       Impact factor: 3.737

6.  Diagnostic values of 2 different techniques for controversial lumbar disc herniation by conventional imaging examination: 3D-DESS vs. CT plain scan.

Authors:  Wei Liu; Jinhua Chen; Yanan Zhang; Xu Wang; Junwen Zheng; Aibing Huang; Chunmao Chen; Jian Bian; Lei Yang; Haijun Li
Journal:  Front Physiol       Date:  2022-09-14       Impact factor: 4.755

  6 in total