Literature DB >> 19351142

Partially buried microcolumns for micro gas analyzers.

Adarsh D Radadia1, Robert D Morgan, Richard I Masel, Mark A Shannon.   

Abstract

This article demonstrates the feasibility of making a partially buried micro gas chromatography (micro-GC) column with a rounded channel wall profile, which enables coating the stationary phase more uniformly and shows better separation characteristics than a square deep reactive ion etched (DRIE) wall profile. A buried structure fabrication method was adapted to fabricate 34 cm long, 165 microm wide, and 65 microm deep partially buried microcolumns, which had a unique rounded microcolumn wall profile similar to that of a flattened circular tube. The separation characteristics were compared to that of a 34 cm long, 100 microm x 100 microm square DRIE microcolumn, which had a similar hydraulic diameter. Minimum height equivalent to a theoretical plate (HETP) and reduced HETP of 0.39 mm and 6.02, respectively, with a retention factor of 6.3 were obtained on the coated partially buried microcolumn compared to 0.66 mm and 6.73, respectively, on the coated square DRIE microcolumn with a similar retention factor. The partially buried microcolumn was found to perform closer to the theoretical approximation and this could be attributed to the uniform phase deposition in the partially buried microcolumn compared to the square DRIE microcolumn. A 10 component mix was separated on the partially buried microcolumn in 3.8 s with the maximum peak width at half-height equal to 0.2 s, while a similar mix separated at higher pressure and temperature conditions on the square DRIE microcolumn in 4.6 s. The rounded corners allowed depositing thinner stationary phase, which was reflected in the faster elution of n-C(12) on the partially buried microcolumn compared to the square DRIE microcolumn. The better performance of the partially buried microcolumn may be attributed to either the rounded channel wall profile, the clean channel structures produced by the fabrication process, or the double-etched wall profile, which lowers the Taylor-Aris dispersion.

Mesh:

Year:  2009        PMID: 19351142     DOI: 10.1021/ac8027382

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

Review 1.  Current methods for detecting ethylene in plants.

Authors:  Simona M Cristescu; Julien Mandon; Denis Arslanov; Jérôme De Pessemier; Christian Hermans; Frans J M Harren
Journal:  Ann Bot       Date:  2012-12-12       Impact factor: 4.357

2.  Characterization of enzymatic micromachining for construction of variable cross-section microchannel topologies.

Authors:  Jen-Huang Huang; Duanduan Han; Molly E Ruggles; Arul Jayaraman; Victor M Ugaz
Journal:  Biomicrofluidics       Date:  2016-05-03       Impact factor: 2.800

3.  A neuron-in-capillary platform for facile collection and mass spectrometric characterization of a secreted neuropeptide.

Authors:  Chang Young Lee; Yi Fan; Stanislav S Rubakhin; Sook Yoon; Jonathan V Sweedler
Journal:  Sci Rep       Date:  2016-06-01       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.