Literature DB >> 19349659

The measurement of small magnetic signals from magnetic nanoparticles attached to the cell surface and surrounding living cells using a general-purpose SQUID magnetometer.

S Hashimoto1, T Oda, K Yamada, M Takagi, T Enomoto, N Ohkohchi, T Takagi, T Kanamori, H Ikeda, H Yanagihara, E Kita, A Tasaki.   

Abstract

Magnetic nanoparticles have recently been widely applied in the bio-medical field. Responding to the demand for a simple and sensitive magnetic assay system for bio-liquid samples, we employed a general-purpose superconducting quantum interference device (SQUID) magnetometer. Strips of filter paper were used as a liquid-specimen sample holder possessing a very small magnetic background signal. An aqueous solution of superparamagnetic iron-oxide nanoparticles (Resovist) was dropped in a tiny blot-like spot in the middle of the filter paper and the magnetization was measured. Magnetic moments of a dilution series of Resovist solutions versus the number of particles provided a linear graph, revealing that the magnetic moment per Resovist particle was 8.25 x 10(-17) emu. 1 x 10(5) cancer cells were incubated with Resovist, and the number of Resovist particles attached to the cell surface and surrounding a living cell was calculated to be 1.02 +/- 0.14 x 10(7) particles/cell. Our system using a commercial SQUID magnetometer should be more than enough to determine the number of magnetic nanoparticles biologically reacting with living cells, contributing to the application of magneto nanomaterials to the life-science field.

Entities:  

Mesh:

Year:  2009        PMID: 19349659     DOI: 10.1088/0031-9155/54/8/021

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Rapid Characterization of Magnetic Moment of Cells for Magnetic Separation.

Authors:  Chinchun Ooi; Christopher M Earhart; Robert J Wilson; Shan X Wang
Journal:  IEEE Trans Magn       Date:  2013-07       Impact factor: 1.700

2.  Magnetic particle detection (MPD) for in-vitro dosimetry.

Authors:  Kevin R Minard; Matthew H Littke; Wei Wang; Yijia Xiong; Justin G Teeguarden; Brian D Thrall
Journal:  Biosens Bioelectron       Date:  2012-12-08       Impact factor: 10.618

3.  (-)-Epicatechin Reduces the Blood Pressure of Young Borderline Hypertensive Rats During the Post-Treatment Period.

Authors:  Michal Kluknavsky; Peter Balis; Martin Skratek; Jan Manka; Iveta Bernatova
Journal:  Antioxidants (Basel)       Date:  2020-01-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.