Literature DB >> 1934926

A study of changes in red cell volume and haemoglobin concentration during phlebotomy induced iron deficiency and iron repletion using the Technicon H1.

W N Patton1, R J Cave, R I Harris.   

Abstract

The recently introduced Technicon H1 analyser uses an improved optical principle to measure the size and haemoglobin concentration of erythrocytes. We have made a serial study of ten patients undergoing phlebotomy to induce mild iron deficiency. The instrument showed the early development of anisohypochromia with subsequent fall in the mean cell haemoglobin concentration (MCHC). Cell volume was preserved until relatively late and during early iron deficient erythropoiesis cell volume would appear to be maintained at the expense of haemoglobin concentration. The Technicon H6000 (conventional technology) used in parallel produced contrasting results indicating anisomicrocytosis with preservation of cell haemoglobin concentration until relatively late. Five cases of severe iron deficiency treated with iron were similarly studied and showed comparable changes on both instruments, with characteristically bimodal cell volume histograms and large increases in red cell distribution width. Our results indicate that the new generation of instruments will generate red cell data of additional clinical value.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1934926     DOI: 10.1111/j.1365-2257.1991.tb00264.x

Source DB:  PubMed          Journal:  Clin Lab Haematol        ISSN: 0141-9854


  4 in total

1.  Milk versus medicine for the treatment of iron deficiency anaemia in hospitalised infants.

Authors:  C R Wall; C C Grant; N Taua; C Wilson; J M D Thompson
Journal:  Arch Dis Child       Date:  2005-06-14       Impact factor: 3.791

2.  Hemoglobin level as a risk factor for lower respiratory tract infections in Lebanese children.

Authors:  Sawsan Mourad; Mariam Rajab; Aouni Alameddine; Mohammad Fares; Fouad Ziade; Bassem Abou Merhi
Journal:  N Am J Med Sci       Date:  2010-10

3.  Identification of iron status of blood donors by using low hemoglobin density and microcytic anemia factor.

Authors:  Ashutosh Singh; Rajendra Chaudhary; Hem C Pandey; Atul Sonker
Journal:  Asian J Transfus Sci       Date:  2018 Jan-Jun

4.  New cut-off values for ferritin and soluble transferrin receptor for the assessment of iron deficiency in children in a high infection pressure area.

Authors:  K S Phiri; J C J Calis; A Siyasiya; I Bates; B Brabin; M Boele van Hensbroek
Journal:  J Clin Pathol       Date:  2009-12       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.