Literature DB >> 19349049

Efficacy and stability performance of traditional versus motion sensor-assisted strategies for FES standing.

G P Braz1, M Russold, R M Smith, G M Davis.   

Abstract

Standing by means of functional electrical stimulation (FES) after spinal cord injury is a topic widely reported in the neurorehabilitation literature. This practice commonly uses surface stimulation over the quadriceps muscle to evoke knee extension. To date, most FES neuroprostheses still operate without any artificial feedback, meaning that after a fatigue-driven knee buckle event, the stimulation amplitude or pulse width must be increased manually via button presses to re-establish knee-lock. This is often referred to as 'hand-controlled (HC) operation'. In an attempt to provide a safer, yet clinically practical approach, this study proposed two novel strategies to automate the control of knee extension based on the kinematic feedback of four miniaturised motion sensors. These strategies were compared to the traditional HC strategy on four individuals with complete paraplegia. The standing times observed over multiple trials were in general longer for the automated strategies when compared to HC (0.5-80%). With the automated strategies, three of the subjects tended to need less upper body support over a frame to maintain balance. A stability analysis based on centre of pressure (CoP) measurements also favoured the automated strategies. This analysis also revealed that although FES standing with the assistance of a frame was likely to be safe for the subjects, their stability was still inferior to that of able-bodied individuals. Overall, the unpredictability of knee buckle events could be more effectively controlled by automated FES strategies to re-establish knee-lock when compared to the traditional user-controlled approach, thus demonstrating the safety and clinical efficacy of an automated approach.

Entities:  

Mesh:

Year:  2009        PMID: 19349049     DOI: 10.1016/j.jbiomech.2009.03.003

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Longitudinal performance of a surgically implanted neuroprosthesis for lower-extremity exercise, standing, and transfers after spinal cord injury.

Authors:  Ronald J Triolo; Stephanie Nogan Bailey; Michael E Miller; Loretta M Rohde; James S Anderson; John A Davis; James J Abbas; Lisa A DiPonio; George P Forrest; David R Gater; Lynda J Yang
Journal:  Arch Phys Med Rehabil       Date:  2012-05       Impact factor: 3.966

Review 2.  Time-interval for integration of stabilizing haptic and visual information in subjects balancing under static and dynamic conditions.

Authors:  Jean-Louis Honeine; Marco Schieppati
Journal:  Front Syst Neurosci       Date:  2014-10-06

3.  Sum of phase-shifted sinusoids stimulation prolongs paralyzed muscle output.

Authors:  Kristen Gelenitis; Max Freeberg; Ronald Triolo
Journal:  J Neuroeng Rehabil       Date:  2020-04-10       Impact factor: 4.262