Literature DB >> 19345645

Use of biocidal products (insect sprays and electro-vaporizer) in indoor areas--exposure scenarios and exposure modeling.

Edith Berger-Preiss1, Wolfgang Koch, Susanne Gerling, Heiko Kock, Klaus E Appel.   

Abstract

Five commercially available insect sprays were applied in a model room. Spraying was performed in accordance with the manufacturers' instructions and in an overdosed manner in order to simulate worst-case conditions or an unforeseeable misuse. In addition, we examined electro-vaporizers. The Respicon aerosol monitoring system was applied to determine inhalation exposure. During normal spraying (10 seconds) and during the following 2-3 minutes, exposure concentrations ranged from 70 to 590 microg/m3 for the pyrethroids tetramethrin, d-phenothrin, cyfluthrin, bioallethrin, and the pyrethrins. Calculated inhalable doses were 2-16 microg. A concentration of approximately 850 microg chlorpyrifos/m(3) (inhalable dose: approximately 20 microg) was determined when the "Contra insect fly spray" was applied. Highest exposure concentrations (1100-2100 microg/m3) were measured for piperonyl butoxide (PBO), corresponding to an inhalation intake of 30-60microg. When simulating worst-case conditions, exposure concentrations of 200-3400microg/m3 and inhalable doses of 10-210microg were determined for the various active substances. Highest concentrations (4800-8000 microg/m3) were measured for PBO (inhalable: 290-480 microg). By applying the electro-vaporizer "Nexa Lotte" plug-in mosquito killer concentrations for d-allethrin were in the range of 5-12microg/m3 and 0.5-2 microg/m3 for PBO while with the "Paral" plug-in mosquito killer concentrations of 0.4-5microg/m3 for pyrethrins and 1-7 microg/m3 for PBO were measured. Potential dermal exposures were determined using exposure pads. Between 80 and 1000microg active substance (tetramethrin, phenothrin, cyfluthrin, bioallethrin, pyrethrins, chlorpyrifos) were deposited on the clothing of the total body surface area of the spray user. Highest levels (up to 3000 microg) were determined for PBO. Worst-case uses of the sprays led to 5-9 times higher concentrations. Also a 2-hour stay nearby an operating electro-vaporizer led to a contamination of the clothing (total amounts on the whole body were 450 microg d-allethrin and 50 microg PBO for "Nexa Lotte" plug-in mosquito killer and 80 microg pyrethrins and 190 microg PBO for "Paral" plug-in mosquito killer). Human biomonitoring data revealed urine concentrations of the metabolite (E)-trans-chrysanthemum dicarboxylic acid ((E)-trans-CDCA) between 1.7 microg/l and 7.1 microg/l after 5 minutes of exposure to the different sprays. Also the use of electro-vaporizers led to (E)-trans-CDCA concentrations in the urine in the range of 1.0 microg/l to 6.2 microg/l (1-3 hours exposure period). The exposure data presented can be used for performing human risk assessment when these biocidal products were applied indoors. The airborne concentrations of the non-volatile active chemical compounds could be predicted from first principles using a deterministic exposure model (SprayExpo).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19345645     DOI: 10.1016/j.ijheh.2009.02.001

Source DB:  PubMed          Journal:  Int J Hyg Environ Health        ISSN: 1438-4639            Impact factor:   5.840


  1 in total

1.  Consumer exposure to biocides--identification of relevant sources and evaluation of possible health effects.

Authors:  Stefan Hahn; Klaus Schneider; Stefan Gartiser; Wolfgang Heger; Inge Mangelsdorf
Journal:  Environ Health       Date:  2010-02-03       Impact factor: 5.984

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.