Literature DB >> 19345518

Dose recalculation and the Dose-Guided Radiation Therapy (DGRT) process using megavoltage cone-beam CT.

Joey Cheung1, Jean-François Aubry, Sue S Yom, Alexander R Gottschalk, Juan Carlos Celi, Jean Pouliot.   

Abstract

PURPOSE: At the University of California San Francisco, daily or weekly three-dimensional images of patients in treatment position are acquired for image-guided radiation therapy. These images can be used for calculating the actual dose delivered to the patient during treatment. In this article, we present the process of performing dose recalculation on megavoltage cone-beam computed tomography images and discuss possible strategies for dose-guided radiation therapy (DGRT).
MATERIALS AND METHODS: A dedicated workstation has been developed to incorporate the necessary elements of DGRT. Patient image correction (cupping, missing data artifacts), calibration, completion, recontouring, and dose recalculation are all implemented in the workstation. Tools for dose comparison are also included. Examples of image correction and dose analysis using 6 head-and-neck and 2 prostate patient datasets are presented to show possible tracking of interfraction dosimetric endpoint variation over the course of treatment.
RESULTS: Analysis of the head-and-neck datasets shows that interfraction treatment doses vary compared with the planning dose for the organs at risk, with the mean parotid dose and spinal cord D(1) increasing by as much as 52% and 10%, respectively. Variation of the coverage to the target volumes was small, with an average D(5) dose difference of 1%. The prostate patient datasets revealed accurate dose coverage to the targeted prostate and varying interfraction dose distributions to the organs at risk.
CONCLUSIONS: An effective workflow for the clinical implementation of DGRT has been established. With these techniques in place, future clinical developments in adaptive radiation therapy through daily or weekly dosimetric measurements of treatment day images are possible.

Entities:  

Mesh:

Year:  2009        PMID: 19345518     DOI: 10.1016/j.ijrobp.2008.12.034

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  8 in total

1.  Surface-constrained nonrigid registration for dose monitoring in prostate cancer radiotherapy.

Authors:  Guillaume Cazoulat; Antoine Simon; Aurelien Dumenil; Khemara Gnep; Renaud de Crevoisier; Oscar Acosta; Pascal Haigron
Journal:  IEEE Trans Med Imaging       Date:  2014-04-01       Impact factor: 10.048

2.  A novel dose-based positioning method for CT image-guided proton therapy.

Authors:  Joey P Cheung; Peter C Park; Laurence E Court; X Ronald Zhu; Rajat J Kudchadker; Steven J Frank; Lei Dong
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

3.  A rapid, accurate image simulation strategy for mega-voltage cone-beam computed tomography.

Authors:  Mengying Shi; Marios Myronakis; Matthew Jacobson; Mathias Lehmann; Dianne Ferguson; Paul Baturin; Pascal Huber; Rony Fueglistaller; Thomas Harris; Ingrid Valencia Lozano; Christopher Williams; Daniel Morf; Ross I Berbeco
Journal:  Phys Med Biol       Date:  2020-07-06       Impact factor: 4.174

4.  Feasibility of MV CBCT-based treatment planning for urgent radiation therapy: dosimetric accuracy of MV CBCT-based dose calculations.

Authors:  Mareike Held; Penny K Sneed; Shannon E Fogh; Jean Pouliot; Olivier Morin
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

5.  On-line dose-guidance to account for inter-fractional motion during proton therapy.

Authors:  Kia Busch; Ludvig P Muren; Sara Thörnqvist; Andreas G Andersen; Jesper Pedersen; Lei Dong; Jørgen B B Petersen
Journal:  Phys Imaging Radiat Oncol       Date:  2018-12-19

Review 6.  ACR Appropriateness Criteria for external beam radiation therapy treatment planning for clinically localized prostate cancer, part II of II.

Authors:  Nicholas G Zaorsky; Timothy N Showalter; Gary A Ezzell; Paul L Nguyen; Dean G Assimos; Anthony V D'Amico; Alexander R Gottschalk; Gary S Gustafson; Sameer R Keole; Stanley L Liauw; Shane Lloyd; Patrick W McLaughlin; Benjamin Movsas; Bradley R Prestidge; Al V Taira; Neha Vapiwala; Brian J Davis
Journal:  Adv Radiat Oncol       Date:  2017-03-20

7.  Accumulating daily-varied dose distributions of prostate radiation therapy with soft-tissue-based kV CT guidance.

Authors:  Andrew Godley; Ergun Ahunbay; Cheng Peng; X Allen Li
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

8.  An investigation into factors affecting electron density calibration for a megavoltage cone-beam CT system.

Authors:  Jessica Hughes; Lois C Holloway; Alexandra Quinn; Andrew Fielding
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.