Optimizing digital radiography of children.

Charles E Willis1.   

Abstract

Pediatric projection imaging differs from imaging of the adult patient. Children are smaller, more radiosensitive, and less compliant than their adult counterparts. Their characteristics affect the way projection imaging is practiced and how dose is optimized. Computed radiography (CR) and digital radiography (DR) have been embraced by pediatric practitioners in order to reduce dose and improve image quality. Unfortunately, dose optimization with CR and DR has been hampered by a lack of definition of appropriate exposure levels, a lack of standardization in exposure factor feedback, and a lack of understanding of the fundamentals of CR and DR technology. The potential for over-exposure exists with both CR and DR. Both the Society for Pediatric Radiology and the American Association of Physicists in Medicine recognize the promise and shortcomings of CR and DR technology and have taken steps to join with manufacturers in improving the practice of CR and DR imaging. Although the risks inherent in pediatric projection imaging with CR and DR are low, efforts to reduce dose are worthwhile, so long as diagnostic quality is maintained. Long-standing recommendations for limiting radiation dose in pediatric projection imaging are still applicable to CR and DR.

Entities:  

Mesh:

Year:  2009        PMID: 19345030     DOI: 10.1016/j.ejrad.2009.03.003

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  5 in total

1.  A survey of digital radiography practice in four South African teaching hospitals: an illuminative study.

Authors:  T Nyathi; Tf Chirwa; Dg van der Merwe
Journal:  Biomed Imaging Interv J       Date:  2010-01-01

2.  Neonatal chest image quality addressed through training to enhance radiographer awareness.

Authors:  Hesta Friedrich-Nel; Belinda van der Merwe; Beatrix Kotzé
Journal:  Health SA       Date:  2018-03-26

3.  Optimizing imaging quality and radiation dose by the age-dependent setting of tube voltage in pediatric chest digital radiography.

Authors:  Hui Guo; Wen-Ya Liu; Xiao-Ye He; Xiao-Shan Zhou; Qun-Li Zeng; Bai-Yan Li
Journal:  Korean J Radiol       Date:  2012-12-28       Impact factor: 3.500

4.  Electronic collimation and radiation protection in paediatric digital radiography: revival of the silver lining.

Authors:  J Bomer; L Wiersma-Deijl; H C Holscher
Journal:  Insights Imaging       Date:  2013-08-28

Review 5.  Digital radiography exposure indices: A review.

Authors:  Ursula Mothiram; Patrick C Brennan; Sarah J Lewis; Bernadette Moran; John Robinson
Journal:  J Med Radiat Sci       Date:  2014-05-11
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.