Literature DB >> 19344946

Operator vs. material influence on clinical outcome of bonded ceramic inlays.

Roland Frankenberger1, Christian Reinelt, Anselm Petschelt, Norbert Krämer.   

Abstract

OBJECTIVE: The aim of the present study was to clinically evaluate the suitability of Definite Multibond and Definite ormocer resin composite for luting of Cergogold glass ceramic inlays in a two-center trial involving two dentists.
METHODS: Thirty-nine patients received 98 Cergogold inlays with at least one inlay luted with Definite Multibond/Definite (n=45) and at least one inlay luted with Syntac/Variolink Ultra (n=53) in a split mouth design. Treatments were carried out in two private practices by two operators (Operator A: n=38; Operator B: n=60). Forty-four cavities required caries profunda treatment, 23 cavities exhibited no enamel at the cervical margin. At baseline (2 months), and after 6, 14, 27, and 51 months of clinical service, the restorations were investigated according to modified USPHS criteria.
RESULTS: The drop-out rate was 3% after 4 years. After 48 months of clinical service, 21 restorations in 16 patients (9 luted with Definite, 12 with Variolink; 2 placed by operator A and 19 by operator B) had to be replaced due to inlay fracture (n=11), tooth fracture (n=4), hypersensitivities (n=3), or marginal gap formation (n=3). Seventy-seven inlays were in good condition (survival rate 89.9%, median survival time 4.2 years (95% confidence interval +/-0.25; survival analysis by Kaplan-Meier algorithm). Survival rate after 4 years was 97.4% for operator A, and 75.4% for operator B (p=0.002; Log Rank/Mantel-Cox) resulting in annual failure rates of 0.6% and 6.2%, respectively. The operators did not differently judge the clinical behaviour of the luting procedures (Mann-Whitney U-test, p>0.05). Independent of the operator and the used luting system, the following criteria significantly changed over time: color match, marginal integrity, tooth integrity, inlay integrity, sensitivity, hypersensitivity, and X-ray control (p<0.05; Friedman test). Significant differences between operators over the whole period were computed for the criteria marginal integrity, tooth integrity, and inlay integrity (p<0.05, Mann-Whitney test). Differences between luting materials were only present during single recalls. SIGNIFICANCES: For luting of ceramic inlays, only slight differences between the two luting systems were detectable. The operator influence on clinical outcome was clearly proven.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19344946     DOI: 10.1016/j.dental.2009.02.002

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  16 in total

1.  Effect of proximal box elevation with resin composite on marginal quality of ceramic inlays in vitro.

Authors:  Roland Frankenberger; Julia Hehn; Jan Hajtó; Norbert Krämer; Michael Naumann; Andreas Koch; Matthias J Roggendorf
Journal:  Clin Oral Investig       Date:  2012-02-23       Impact factor: 3.573

2.  Four-year clinical evaluation of a self-adhesive luting agent for ceramic inlays.

Authors:  Marleen Peumans; M Voet; J De Munck; K Van Landuyt; A Van Ende; B Van Meerbeek
Journal:  Clin Oral Investig       Date:  2012-06-17       Impact factor: 3.573

3.  Effect of microparticulate silver addition in dental adhesives on secondary caries in vitro.

Authors:  Norbert Krämer; Mandy Möhwald; Susanne Lücker; Eugen Domann; José I Zorzin; Martin Rosentritt; Roland Frankenberger
Journal:  Clin Oral Investig       Date:  2015-01-24       Impact factor: 3.573

4.  Glass ionomer cement inhibits secondary caries in an in vitro biofilm model.

Authors:  Norbert Krämer; Miriam Schmidt; Susanne Lücker; Eugen Domann; Roland Frankenberger
Journal:  Clin Oral Investig       Date:  2017-07-24       Impact factor: 3.573

5.  Effect of selective enamel etching on clinical performance of CAD/CAM partial ceramic crowns luted with a self-adhesive resin cement.

Authors:  Marianne Federlin; Karl-Anton Hiller; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2014-01-10       Impact factor: 3.573

6.  Controlled, prospective, randomized, clinical split-mouth evaluation of partial ceramic crowns luted with a new, universal adhesive system/resin cement: results after 18 months.

Authors:  Vanessa Vogl; Karl-Anton Hiller; Wolfgang Buchalla; Marianne Federlin; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2016-03-12       Impact factor: 3.573

7.  Controlled, prospective, randomized, clinical evaluation of partial ceramic crowns inserted with RelyX Unicem with or without selective enamel etching. Results after 2 years.

Authors:  Frederike Schenke; Marianne Federlin; Karl-Anton Hiller; Daniel Moder; Gottfried Schmalz
Journal:  Clin Oral Investig       Date:  2011-03-23       Impact factor: 3.573

8.  Influence of Practitioner-Related Placement Variables on the Compressive Properties of Bulk-Fill Composite Resins-An In Vitro Clinical Simulation Study.

Authors:  Tamar Brosh; Moshe Davidovitch; Avi Berg; Aviran Shenhav; Raphael Pilo; Shlomo Matalon
Journal:  Materials (Basel)       Date:  2022-06-17       Impact factor: 3.748

9.  The effect of diabetes on the tensile bond strength of a restorative dental composite to dentin.

Authors:  Mohammad Ali Saghiri; Peter Freag; Devyani Nath; Steven M Morgano
Journal:  Odontology       Date:  2022-03-04       Impact factor: 2.885

10.  Efficacy of composite versus ceramic inlays and onlays: study protocol for the CECOIA randomized controlled trial.

Authors:  Hélène Fron Chabouis; Caroline Prot; Cyrille Fonteneau; Karim Nasr; Olivier Chabreron; Stéphane Cazier; Christian Moussally; Alexandre Gaucher; Inès Khabthani Ben Jaballah; Renaud Boyer; Jean-François Leforestier; Aurore Caumont-Prim; Florence Chemla; Louis Maman; Cathy Nabet; Jean-Pierre Attal
Journal:  Trials       Date:  2013-09-03       Impact factor: 2.279

View more