Use of the AngioSculpt scoring balloon for infrapopliteal lesions in patients with critical limb ischemia: 1-year outcome.

Marc Bosiers1, Koen Deloose, Catherine Cagiannos, Jürgen Verbist, Patrick Peeters.   

Abstract

The AngioSculpt Scoring Balloon Catheter (AngioScore, Inc., Fremont, CA) is composed of a semicompliant balloon encircled by three nitinol spiral struts providing targeted lesion scoring on balloon inflation. Between April 2005 and April 2006, procedural and follow-up data on 31 patients (mean age 76 years; 54.8% males) endovascularly treated for severe infrapopliteal disease were collected. The AngioSculpt catheter was used to treat 36 complex, tibioperoneal, atherosclerotic lesions. All patients had symptomatic critical limb ischemia (Rutherford 4-5) and single-vessel runoff to the ankle. Complication-free survival at 1 month was the safety end point, whereas primary patency and limb salvage were the efficacy end points evaluated at 1 year. The AngioSculpt balloon was successfully inflated in all 36 target lesions. Eleven patients (35.5%) required additional stenting for minor dissections or suboptimal stenosis reduction. The 1-month complication-free survival was 96.8%. One-year survival, primary patency, and limb salvage rates were 83.9 +/- 6.6%, 61.0 +/- 9.3%, and 86.3 +/- 6.4%, respectively. The 1-year data show the AngioSculpt Scoring Balloon Catheter to be an effective and safe treatment for infrapopliteal, atherosclerotic lesions in patients with critical limb ischemia. However, more patients, a longer follow-up, and randomized studies comparing it with conventional balloon angioplasty and stenting in the infrapopliteal region are required.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19344580     DOI: 10.2310/6670.2009.00001

Source DB:  PubMed          Journal:  Vascular        ISSN: 1708-5381            Impact factor:   1.285


  4 in total

1.  Long-term outcome upon treatment of calcified lesions of the lower limb using scoring angioplasty balloon (AngioSculpt™).

Authors:  Mariya Kronlage; Carolin Werner; Matthias Dufner; Erwin Blessing; Oliver J Müller; Britta Heilmeier; Hugo A Katus; Christian Erbel
Journal:  Clin Res Cardiol       Date:  2020-02-08       Impact factor: 5.460

Review 2.  [Current Strategy in Endovascular Management for Below-the-Knee Arterial Lesions].

Authors:  Kyosoo Hwang; Sang Woo Park
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2021-05-28

3.  The conundrum of endovascular common femoral artery treatment: a case report of lithoplasty as a viable solution.

Authors:  Carlo Trani; Giulio Russo; Cristina Aurigemma; Francesco Burzotta
Journal:  Eur Heart J Case Rep       Date:  2019-07-29

4.  Combination therapy using scoring and sirolimus drug-coated balloons during lower limb endovascular revascularization for chronic limb threatening ischaemia: A case series.

Authors:  Tiffany Sh Bong; Charyl Jq Yap; Shereen Xy Soon; Tjun Y Tang
Journal:  SAGE Open Med Case Rep       Date:  2022-03-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.