Literature DB >> 19344148

Potential primary measurement tool for the quantification of DNA.

Ryan G Brennan1, Savelas A Rabb, Marcia J Holden, Michael R Winchester, Gregory C Turk.   

Abstract

An automated sample introduction system, utilizing a demountable direct injection high-efficiency nebulizer (d-DIHEN), is successfully incorporated for the first time with an inductively coupled plasma optical emission spectrometer (ICP-OES) for the measurement of the phosphorus content in acid-digested nucleotides and deoxyribonucleic acid (DNA). With this experimental setup, the solution uptake rate and volume are reduced from 170 to 30 microL min(-1) and from 10 to 2.4 mL, respectively, thereby reducing the required DNA sample mass for solutions containing 3 microg g(-1) P from 300 to 72 microg of DNA, in comparison to previous analyses in our laboratory using a glass concentric nebulizer with cyclonic spray chamber arrangement. The use of direct injection also improves P (I) 213.617 nm sensitivity by a factor of 4 on average. A high-performance (HP) methodology in combination with the previous sample introduction system and ICP-OES provides simultaneous, time-correlated internal standardization and drift correction resulting in relative expanded uncertainties (% U) for the P mass fractions in the range of 0.1-0.4 (95% confidence level) for most of the thymidine 5'-monophosphate (TMP), calf thymus DNA (CTDNA), and plasmid DNA (PLDNA) analyses. The d-DIHEN with HP-ICP-OES methodology allows for the quantification of DNA mass at P mass fractions as low as 0.5 microg g(-1), further reducing the required DNA mass to 12 microg, with small uncertainty (< or = 0.4%). This successful approach will aid in the development and certification of nucleic acid certified reference materials (CRMs), particularly for these samples that are typically limited in volume.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19344148     DOI: 10.1021/ac802688x

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Molecular characterization, gas chromatography mass spectrometry analysis, phytochemical screening and insecticidal activities of ethanol extract of Lentinus squarrosulus against Aedes aegypti (Linnaeus).

Authors:  Morenike Olutumbi Adeoye-Isijola; Segun Gbolagade Jonathan; Roger Murugas Coopoosamy; Olufunmiso Olusola Olajuyigbe
Journal:  Mol Biol Rep       Date:  2021-01-17       Impact factor: 2.316

2.  Accurate quantitation standards of glutathione via traceable sulfur measurement by inductively coupled plasma optical emission spectrometry and ion chromatography.

Authors:  L Rastogi; K Dash; J Arunachalam
Journal:  J Pharm Anal       Date:  2013-03-05

3.  DNA extract characterization process for microbial detection methods development and validation.

Authors:  Nathan D Olson; Jayne B Morrow
Journal:  BMC Res Notes       Date:  2012-12-03

4.  Quantification of plasmid DNA reference materials for Shiga toxin-producing Escherichia coli based on UV, HR-ICP-MS and digital PCR.

Authors:  Wen Liang; Li Xu; Zhiwei Sui; Yan Li; Lanying Li; Yanli Wen; Chunhua Li; Shuzhen Ren; Gang Liu
Journal:  Chem Cent J       Date:  2016-09-12       Impact factor: 4.215

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.