Literature DB >> 19343704

Automatic extraction of proximal femur contours from calibrated X-ray images using 3D statistical models: an in vitro study.

Xiao Dong1, Guoyan Zheng.   

Abstract

BACKGROUND: Accurate extraction of bone contours from two-dimensional (2D) projective X-ray images is an important component for computer-assisted diagnosis, planning or three-dimensional (3D) reconstruction.
METHODS: We propose a 3D statistical model-based, fully automatic segmentation framework for extracting the proximal femur contours from calibrated X-ray images. The automatic initialization is an estimation of a Bayesian network algorithm to fit a multiple-component geometrical model to the X-ray data. The contour extraction is accomplished by a non-rigid 2D/3D registration between the statistical model and the X-ray images, in which bone contours are extracted by a graphical model-based Bayesian inference.
RESULTS: The contour extraction algorithm was verified on both cadaver and clinical datasets, visually and quantitatively. Compared to the 'gold standard', a mean error of 1.6 mm was observed when the automatically extracted contours were used to reconstruct a patient-specific surface model.
CONCLUSIONS: Our statistical model-based bone contour extraction approach holds the potential to facilitate the application of 2D/3D reconstruction in surgical navigation.

Entities:  

Mesh:

Year:  2009        PMID: 19343704     DOI: 10.1002/rcs.253

Source DB:  PubMed          Journal:  Int J Med Robot        ISSN: 1478-5951            Impact factor:   2.547


  4 in total

1.  Group average difference: a termination criterion for active contour.

Authors:  Tong Kuan Chuah; Jun Hong Lim; Chueh Loo Poh
Journal:  J Digit Imaging       Date:  2012-04       Impact factor: 4.056

2.  Principal component analysis in construction of 3D human knee joint models using a statistical shape model method.

Authors:  Tsung-Yuan Tsai; Jing-Sheng Li; Shaobai Wang; Pingyue Li; Young-Min Kwon; Guoan Li
Journal:  Comput Methods Biomech Biomed Engin       Date:  2013-10-24       Impact factor: 1.763

3.  Reliability and concurrent validity of angle measurements in lower limb: EOS 3D goniometer versus 2D manual goniometer.

Authors:  Jun Huang; Fanli Tian; Zhigang Zhang; Weidong Shi; Jun Lin; Liang Chen; Huilin Yang
Journal:  J Orthop Translat       Date:  2020-05-20       Impact factor: 5.191

4.  Segmentation of radiographic images under topological constraints: application to the femur.

Authors:  Pavan Gamage; Sheng Quan Xie; Patrice Delmas; Wei Liang Xu
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-01-28       Impact factor: 2.924

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.