Literature DB >> 19342960

Effect of abdominal aortic grafts on aortic stiffness and central hemodynamics.

Pierre Lantelme1, Anastase Dzudie, Hugues Milon, Giampiero Bricca, Liliana Legedz, Jean-Michel Chevalier, Patrick Feugier.   

Abstract

Graft-prosthesis and stentgraft placements are effective modalities for treating abdominal aortic aneurysm, but related changes in arterial stiffness are not well established. The present study sought to assess aortic stiffness after aneurism repair by measuring pulse wave velocity (PWV). The graft-related variation of carotid-femoral PWV was compared with that of carotid-radial PWV, the latter being unaffected by vascular treatment. The secondary objective was to evaluate potential differences between graft-prosthesis and stentgraft in terms of aortic stiffness and augmentation index, a composite indicator integrating wave reflexion. Fifty patients were included (39 had a graft-prosthesis and 11 had a stentgraft). In the whole group and after a median postoperative follow-up of 47 days, carotid-femoral PWV increased by +1.0 m/s [-12.3, +10.3], while carotid-radial PWV slightly decreased by -0.3 m/s [-4.4; +3.5] (P = 0.001). The effect of the type of prosthesis on the PWV was not significant. Nevertheless, the augmentation index increased after stentgraft implantation (+4% [-10; +17]) and decreased after graft-prosthesis placement (-8.5% [-47; +17]) (P < 0.01). This difference was not explained by a heart rate or a treatment effect and was likely attributable to the prosthesis per se. This study demonstrates the impact of aortic grafts on aortic stiffness. Besides, it suggests that stentgraft increases reflected waves more than graft-prostheses. These changes of vascular properties may influence the outcomes after surgery.

Entities:  

Mesh:

Year:  2009        PMID: 19342960     DOI: 10.1097/HJH.0b013e3283299b22

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  10 in total

Review 1.  A critical appraisal of endovascular stent-grafts in the management of abdominal aortic aneurysms.

Authors:  Nikolaos Schoretsanitis; Efstratios Georgakarakos; Christos Argyriou; Kiriakos Ktenidis; George S Georgiadis
Journal:  Radiol Med       Date:  2017-01-21       Impact factor: 3.469

2.  Effect of endoskeleton stent graft design on pulse wave velocity in patients undergoing endovascular repair of the aortic arch.

Authors:  Daijiro Hori; Kei Akiyoshi; Koichi Yuri; Satoshi Nishi; Takao Nonaka; Takahiro Yamamoto; Yusuke Imamura; Harunobu Matsumoto; Naoyuki Kimura; Atsushi Yamaguchi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-06-08

3.  Perioperative factors associated with aneurysm sac size changes after endovascular aneurysm repair.

Authors:  Daijiro Hori; Yohei Nomura; Taketo Yamauchi; Hiroshi Furuhata; Harunobu Matsumoto; Naoyuki Kimura; Koichi Yuri; Atsushi Yamaguchi
Journal:  Surg Today       Date:  2018-09-12       Impact factor: 2.549

4.  Functional Evaluation of Embedded Modular Single-Branched Stent Graft: Application to Type B Aortic Dissection With Aberrant Right Subclavian Artery.

Authors:  Xuehuan Zhang; Duanduan Chen; Mingwei Wu; Huiwu Dong; Zhengdong Wan; Heyue Jia; Shichao Liang; Jun Shao; Jun Zheng; Shangdong Xu; Jiang Xiong; Wei Guo
Journal:  Front Cardiovasc Med       Date:  2022-05-02

Review 5.  Medical Textiles as Vascular Implants and Their Success to Mimic Natural Arteries.

Authors:  Charanpreet Singh; Cynthia S Wong; Xungai Wang
Journal:  J Funct Biomater       Date:  2015-06-30

6.  Development of Coronary Pulse Wave Velocity: New Pathophysiological Insight Into Coronary Artery Disease.

Authors:  Brahim Harbaoui; Pierre-Yves Courand; Andrei Cividjian; Pierre Lantelme
Journal:  J Am Heart Assoc       Date:  2017-02-02       Impact factor: 5.501

7.  Chronic ETA antagonist reverses hypertension and impairment of structure and function of peripheral small arteries in aortic stiffening.

Authors:  Xiaomei Guo; Huan Chen; Ling Han; Stephan Haulon; Ghassan S Kassab
Journal:  Sci Rep       Date:  2018-02-15       Impact factor: 4.379

8.  Reflected wave intensity increases based on aortic diameter after endovascular aortic therapy in a goat model.

Authors:  Tomohiro Takano; Masumi Iwai-Takano; Yusuke Tsuboko; Yasuyuki Shiraishi; Tomoyuki Yambe; Takashi Igarashi; Hitoshi Yokoyama
Journal:  Sci Rep       Date:  2021-02-15       Impact factor: 4.379

9.  Association of impaired arterial wall properties with the presence of coronary artery disease in patients with abdominal aortic aneurysms.

Authors:  Pinelopi Rafouli-Stergiou; Ignatios Ikonomidis; Niki Katsiki; Nikolaos P E Kadoglou; Stefanos Vlachos; John Thymis; John Parissis; Konstantinos G Moulakakis; John D Kakisis
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-02-12       Impact factor: 3.738

10.  Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft.

Authors:  Efstratios Georgakarakos; Christos Argyriou; George S Georgiadis; Miltos K Lazarides
Journal:  Front Surg       Date:  2016-01-11
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.