Literature DB >> 19342331

A wireless bio-MEMS sensor for C-reactive protein detection based on nanomechanics.

Chun-Hao Chen1, Rong-Zhang Hwang, Long-Sun Huang, Shi-Ming Lin, Hsiao-Chin Chen, Yu-Che Yang, Yu-Tso Lin, Shih-An Yu, Yo-Sheng Lin, Yiao-Hong Wang, Nai-Kuan Chou, Shey-Shi Lu.   

Abstract

A quick wireless label-free detection of disease-related C-reactive proteins (CRPs) using a 200-microm-long microelectromechanical systems (MEMS) microcantilever housed in a 7 x 7 mm(2) reaction chamber with a safe reusable feature is reported. The assay time ranges from about 30 min to 3 h, depending on accuracy. The deflection of the microcantilever due to specific CRP-antiCRP binding is detected using a position-sensitive detector. The converted bio-signal is transmitted by a custom designed wireless amplitude-shift-keying (ASK) transceiver IC fabricated in a 0.18 microm CMOS process. CRP concentrations from 1 microg/mL to 500 microg/mL can be detected. A 0.2-Hz 1-V ac signal instead of traditional bases/acids is applied to the bio-MEMS sensor to unbind the CRP from the microcantilever for reusability.

Mesh:

Substances:

Year:  2009        PMID: 19342331     DOI: 10.1109/TBME.2008.2003262

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  5 in total

Review 1.  Biosensors for Detection of Human Placental Pathologies: A Review of Emerging Technologies and Current Trends.

Authors:  Jia Liu; Babak Mosavati; Andrew V Oleinikov; E Du
Journal:  Transl Res       Date:  2019-05-20       Impact factor: 7.012

2.  Chip implementation with a combined wireless temperature sensor and reference devices based on the DZTC principle.

Authors:  Ming-Hui Chang; Yu-Jie Huang; Han-Pang Huang; Shey-Shi Lu
Journal:  Sensors (Basel)       Date:  2011-10-31       Impact factor: 3.576

Review 3.  Modulation techniques for biomedical implanted devices and their challenges.

Authors:  Mahammad A Hannan; Saad M Abbas; Salina A Samad; Aini Hussain
Journal:  Sensors (Basel)       Date:  2011-12-28       Impact factor: 3.576

4.  Electrical detection of C-reactive protein using a single free-standing, thermally controlled piezoresistive microcantilever for highly reproducible and accurate measurements.

Authors:  Yi-Kuang Yen; Yu-Cheng Lai; Wei-Ting Hong; Yotsapoom Pheanpanitporn; Chuin-Shan Chen; Long-Sun Huang
Journal:  Sensors (Basel)       Date:  2013-07-29       Impact factor: 3.576

5.  Simulation of an electrically actuated cantilever as a novel biosensor.

Authors:  Masoud SoltanRezaee; Mahdi Bodaghi
Journal:  Sci Rep       Date:  2020-02-25       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.