Literature DB >> 19341370

The influence of wellbore inflow on electromagnetic borehole flowmeter measurements.

Tom Clemo1, Warren Barrash, Edward C Reboulet, Timothy C Johnson, Carsten Leven.   

Abstract

This paper describes a combined field, laboratory, and numerical study of electromagnetic borehole flowmeter measurements acquired without the use of a packer or skirt to block bypass flow around the flowmeter. The most significant finding is that inflow through the wellbore screen changes the ratio of flow through the flowmeter to wellbore flow. Experiments reveal up to a factor of two differences in this ratio for conditions with and without inflow through the wellbore screen. Standard practice is to assume the ratio is constant. A numerical model has been developed to simulate the effect of inflow on the flowmeter. The model is formulated using momentum conservation within the borehole and around the flowmeter. The model is embedded in the MODFLOW-2000 ground water flow code.

Entities:  

Mesh:

Year:  2009        PMID: 19341370     DOI: 10.1111/j.1745-6584.2008.00559.x

Source DB:  PubMed          Journal:  Ground Water        ISSN: 0017-467X            Impact factor:   2.671