Phase retrieval with signal bias.

Samuel T Thurman1, James R Fienup.   

Abstract

The effect of a uniform measurement bias, due to background light, stray light, detector dark current, or detector offset, on phase retrieval wavefront sensing algorithms is analyzed. Simulation results indicate that the root-mean-square error of the retrieved phase can be more sensitive to an unaccounted-for signal bias than to random noise in practical scenarios. Three methods for reducing the impact of signal bias are presented.

Year:  2009        PMID: 19340276     DOI: 10.1364/josaa.26.001008

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  2 in total

1.  Closed loop adaptive optics for microscopy without a wavefront sensor.

Authors:  Peter Kner; Lukman Winoto; David A Agard; John W Sedat
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2010-02-24

2.  Non-invasive imaging through opaque scattering layers.

Authors:  Jacopo Bertolotti; Elbert G van Putten; Christian Blum; Ad Lagendijk; Willem L Vos; Allard P Mosk
Journal:  Nature       Date:  2012-11-08       Impact factor: 49.962

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.