Literature DB >> 19336296

Real-time FPGA processing for high-speed optical frequency domain imaging.

Adrien E Desjardins1, Benjamin J Vakoc, Melissa J Suter, Seok-Hyun Yun, Guillermo J Tearney, Brett E Bouma.   

Abstract

We present a novel algorithm for reconstructing interferograms acquired in optical frequency domain imaging (OFDI). The algorithm was developed specifically for processing in field programmable gate arrays (FPGAs) and featured the use of a finite-impulse-response (FIR) filter implementation of B-spline interpolation for efficiently re-sampling k-space. When implemented in FPGAs, the algorithm allowed for real-time processing of interferograms acquired with a high-speed OFDI system at 54 kHz and a sampling rate of 100 MS/s.

Entities:  

Mesh:

Year:  2009        PMID: 19336296      PMCID: PMC2883772          DOI: 10.1109/TMI.2009.2017740

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  14 in total

1.  Real-time digital signal processing-based optical coherence tomography and Doppler optical coherence tomography.

Authors:  Alexander W Schaefer; J Joshua Reynolds; Daniel L Marks; Stephen A Boppart
Journal:  IEEE Trans Biomed Eng       Date:  2004-01       Impact factor: 4.538

2.  Comprehensive volumetric optical microscopy in vivo.

Authors:  Seok H Yun; Guillermo J Tearney; Benjamin J Vakoc; Milen Shishkov; Wang Y Oh; Adrien E Desjardins; Melissa J Suter; Raymond C Chan; John A Evans; Ik-Kyung Jang; Norman S Nishioka; Johannes F de Boer; Brett E Bouma
Journal:  Nat Med       Date:  2006-11-19       Impact factor: 53.440

3.  115 kHz tuning repetition rate ultrahigh-speed wavelength-swept semiconductor laser.

Authors:  W Y Oh; S H Yun; G J Tearney; B E Bouma
Journal:  Opt Lett       Date:  2005-12-01       Impact factor: 3.776

4.  Comprehensive esophageal microscopy by using optical frequency-domain imaging (with video).

Authors:  Benjamin J Vakoc; Milen Shishko; Seok H Yun; Wang-Yuhl Oh; Melissa J Suter; Adrien E Desjardins; John A Evans; Norman S Nishioka; Guillermo J Tearney; Brett E Bouma
Journal:  Gastrointest Endosc       Date:  2007-03-26       Impact factor: 9.427

5.  Efficient implementation of all-digital interpolation.

Authors:  B Vrcej; P P Vaidyanathan
Journal:  IEEE Trans Image Process       Date:  2001       Impact factor: 10.856

6.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography.

Authors:  Michael Choma; Marinko Sarunic; Changhuei Yang; Joseph Izatt
Journal:  Opt Express       Date:  2003-09-08       Impact factor: 3.894

7.  Performance of fourier domain vs. time domain optical coherence tomography.

Authors:  R Leitgeb; C Hitzenberger; Adolf Fercher
Journal:  Opt Express       Date:  2003-04-21       Impact factor: 3.894

8.  Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting.

Authors:  S Yun; G Tearney; J de Boer; B Bouma
Journal:  Opt Express       Date:  2004-10-04       Impact factor: 3.894

9.  Instantaneous complex conjugate resolved spectral domain and swept-source OCT using 3x3 fiber couplers.

Authors:  Marinko Sarunic; Michael A Choma; Changhuei Yang; Joseph A Izatt
Journal:  Opt Express       Date:  2005-02-07       Impact factor: 3.894

10.  In vivo optical frequency domain imaging of human retina and choroid.

Authors:  Edward C Lee; Johannes F de Boer; Mircea Mujat; Hyungsik Lim; Seok H Yun
Journal:  Opt Express       Date:  2006-05-15       Impact factor: 3.894

View more
  8 in total

1.  Improving sensitivity in nonlinear Raman microspectroscopy imaging and sensing.

Authors:  Rajan Arora; Georgi I Petrov; Jian Liu; Vladislav V Yakovlev
Journal:  J Biomed Opt       Date:  2011-02       Impact factor: 3.170

2.  High-performance multi-megahertz optical coherence tomography based on amplified optical time-stretch.

Authors:  Jingjiang Xu; Xiaoming Wei; Luoqin Yu; Chi Zhang; Jianbing Xu; K K Y Wong; Kevin K Tsia
Journal:  Biomed Opt Express       Date:  2015-03-18       Impact factor: 3.732

Review 3.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

4.  High-speed spectral calibration by complex FIR filter in phase-sensitive optical coherence tomography.

Authors:  Sangmin Kim; Patrick D Raphael; John S Oghalai; Brian E Applegate
Journal:  Biomed Opt Express       Date:  2016-03-21       Impact factor: 3.732

5.  GPU accelerated real-time multi-functional spectral-domain optical coherence tomography system at 1300 nm.

Authors:  Yan Wang; Christian M Oh; Michael C Oliveira; M Shahidul Islam; Arthur Ortega; B Hyle Park
Journal:  Opt Express       Date:  2012-07-02       Impact factor: 3.894

6.  Graphics processing unit accelerated non-uniform fast Fourier transform for ultrahigh-speed, real-time Fourier-domain OCT.

Authors:  Kang Zhang; Jin U Kang
Journal:  Opt Express       Date:  2010-10-25       Impact factor: 3.894

7.  High-speed camera with real time processing for frequency domain imaging.

Authors:  Victor Shia; David Watt; Gregory W Faris
Journal:  Biomed Opt Express       Date:  2011-06-15       Impact factor: 3.732

8.  Spectral domain optical coherence tomography of multi-MHz A-scan rates at 1310 nm range and real-time 4D-display up to 41 volumes/second.

Authors:  Dong-Hak Choi; Hideaki Hiro-Oka; Kimiya Shimizu; Kohji Ohbayashi
Journal:  Biomed Opt Express       Date:  2012-11-01       Impact factor: 3.732

  8 in total