Literature DB >> 19332420

Screen for intracranial dural arteriovenous fistulae with carotid duplex sonography.

L-K Tsai1, S-J Yeh, Y-C Chen, H-M Liu, J-S Jeng.   

Abstract

OBJECTIVES: Early diagnosis and management of intracranial dural arteriovenous fistulae (DAVF) may prevent the occurrence of stroke. This study aimed to identify the best carotid duplex sonography (CDS) parameters for screening DAVF.
METHODS: 63 DAVF patients and 170 non-DAVF patients received both CDS and conventional angiography. The use of seven CDS haemodynamic parameter sets related to the resistance index (RI) of the external carotid artery (ECA) for the diagnosis of DAVF was validated and the applicability of the best CDS parameter set in 20 400 patients was tested.
RESULTS: The CDS parameter set (ECA RI (cut-off point = 0.7) and internal carotid artery (ICA) to ECA RI ratio (cut-off point = 0.9)) had the highest specificity (99%) for diagnosis of DAVF with moderate sensitivity (51%). Location of the DAVF was a significant determinant of sensitivity of detection, which was 70% for non-cavernous DAVF and 0% for cavernous sinus DAVF (p<0.001). The above parameter set detected abnormality in 92 of 20 400 patients. These abnormalities included DAVF (n = 25), carotid stenosis (n = 32), vertebral artery stenosis (n = 7), intracranial arterial stenosis (n = 6), head and neck tumour (n = 3) and unknown aetiology (n = 19).
CONCLUSION: Combined CDS parameters of ECA RI and ICA to ECA RI ratio can be used as a screening tool for the diagnosis of DAVF.

Entities:  

Mesh:

Year:  2009        PMID: 19332420     DOI: 10.1136/jnnp.2008.166413

Source DB:  PubMed          Journal:  J Neurol Neurosurg Psychiatry        ISSN: 0022-3050            Impact factor:   10.154


  4 in total

1.  The role of the occipital artery in the diagnosis of intracranial dural arteriovenous fistula using duplex sonography.

Authors:  B-L Tee; L-K Tsai; C-C Lai; S-C Tang; Y-A Chen; C-L Chen; J-S Jeng
Journal:  AJNR Am J Neuroradiol       Date:  2012-09-13       Impact factor: 3.825

2.  Usefulness of end-diastolic ratio in carotid ultrasonography for the screening of dural arteriovenous fistula: a case series.

Authors:  Toshiaki Goda; Junya Kobayashi; Nobuyuki Ohara; Takeshi Ikegami; Kotaro Watanabe; Daisuke Takahashi
Journal:  J Med Ultrason (2001)       Date:  2017-03-14       Impact factor: 1.314

Review 3.  Point-of-care ultrasound for stroke patients in the emergency room.

Authors:  Hidehiro Takekawa; Daisuke Tsukui; Saro Kobayasi; Keisuke Suzuki; Hirotoshi Hamaguchi
Journal:  J Med Ultrason (2001)       Date:  2022-02-03       Impact factor: 1.314

4.  Elevated end-diastolic ratio of the common carotid artery due to cerebral arteriovenous malformation: Two case reports.

Authors:  Koji Tanaka; Shoji Matsumoto; Takeshi Yamada; Daisuke Kondo; Hideo Chihara; Motohisa Koga; Taketo Hatano; Tomoya Miyagi; Ryo Yamasaki; Jun-Ichi Kira
Journal:  Radiol Case Rep       Date:  2018-07-13
  4 in total