Literature DB >> 19329510

A new lead-free radiation shielding material for radiotherapy.

Kun Yue1, Wenyun Luo, Xiaoqing Dong, Chuanshan Wang, Guohua Wu, Mawei Jiang, Yuanzi Zha.   

Abstract

Lead has recently been recognised as a source of environmental pollution, including the lead used for radiation shielding in radiotherapy. The bremsstrahlung radiation caused by the interaction between the electron beam and lead may reduce the accuracy of radiotherapy. To avoid the use of lead, a new material composed of tungsten and hydrogenated styrene-butadiene-styrene copolymer is studied with the Monte Carlo (MC) method and experiment in this paper. The component of the material is chosen after simulation with the MC method and the practical measurement is taken to validate the shielding ability of the material. The result shows that the shielding ability of the new material is good enough to fulfill the requirement for application in radiotherapy. Compared with lead alloy, the present new material is so flexible that can be easily customized into arbitrary shapes. Moreover, the material is environmentally friendly and can be recycled conveniently. Therefore, the material can be used as an effective lead substitute for shielding against electron beams in radiotherapy.

Mesh:

Substances:

Year:  2009        PMID: 19329510     DOI: 10.1093/rpd/ncp053

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Assessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation.

Authors:  M Kazempour; M Saeedimoghadam; F Shekoohi Shooli; N Shokrpour
Journal:  J Biomed Phys Eng       Date:  2015-06-01

2.  A Monte Carlo Study on the Shielding Properties of a Novel Polyvinyl Alcohol (PVA)/WO3 Composite, Against Gamma Rays, Using the MCNPX Code.

Authors:  Kazemi F; Malekie S; Hosseini M A
Journal:  J Biomed Phys Eng       Date:  2019-08-01

3.  Evaluation of lead equivalence of radiation protection apparatuses as a function of tube potential and spectral shaping filter.

Authors:  Areej Fawzi Aljabal; Richard Ryan Wargo; Pei-Jan Paul Lin
Journal:  J Appl Clin Med Phys       Date:  2019-11-18       Impact factor: 2.102

4.  Calculation of Attenuation Parameter for Ir-192 Gamma Source in Shielding Materials.

Authors:  Adila Hanim Aminordin Sabri; M Z Abdul Aziz; S F Olukotun; S M Tajudin
Journal:  J Med Phys       Date:  2022-03-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.