Literature DB >> 19329455

Ultrasonic scaler oscillations and tooth-surface defects.

S C Lea1, B Felver, G Landini, A D Walmsley.   

Abstract

Damage to tooth root surfaces may occur during ultrasonic cleaning with both piezoelectric and magnetostrictive ultrasonic scalers. It is unclear which mechanism causes more damage or how their mechanism of action leads to such damage. Our null hypothesis is that tooth-surface defect dimensions, resulting from instrumentation with ultrasonic scalers, are independent of whether the scaler probe is magnetostrictive or piezoelectric. Piezoelectric and magnetostrictive ultrasonic scaler probes were placed into contact against polished dentin samples (100 g/200 g). Resulting tooth surfaces were evaluated with a laser metrology system. Ultrasonic instrumentation produced an indentation directly related to the bodily movement of the probe as it made an impact on the surface. Load, generator power, and probe cross-section significantly affected probe vibration and defect depth/volume. Defect dimensions were independent of generator type. Magnetostrictive probes oscillated with greater displacement amplitudes than piezoelectric probes, but produced similar defects. This may be due to the cross-sectional shape of the probes.

Entities:  

Mesh:

Year:  2009        PMID: 19329455     DOI: 10.1177/0022034508330267

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  8 in total

1.  Comparison of Penetration of Irrigant Activated by Traditional Methods with A Novel Technique.

Authors:  Pavan Kumar Kanumuru; Sujatha Gopal Sooraparaju; Karthik Roy Konda; Surya Kumari Nujella; Bala Kasi Reddy; Siva Ram Penigalapati
Journal:  J Clin Diagn Res       Date:  2015-11-01

2.  Mapping cavitation activity around dental ultrasonic tips.

Authors:  A Damien Walmsley; Simon C Lea; Bernhard Felver; David C King; Gareth J Price
Journal:  Clin Oral Investig       Date:  2012-08-15       Impact factor: 3.573

3.  Evaluation of smear layer and debris removal by stepwise intraoperative activation (SIA) of sodium hypochlorite.

Authors:  G Plotino; M Colangeli; T Özyürek; G DeDeus; C Panzetta; R Castagnola; N M Grande; L Marigo
Journal:  Clin Oral Investig       Date:  2020-06-05       Impact factor: 3.573

4.  Potential of shock waves to remove calculus and biofilm.

Authors:  Philipp Müller; Bernhard Guggenheim; Thomas Attin; Ernst Marlinghaus; Patrick R Schmidlin
Journal:  Clin Oral Investig       Date:  2010-09-07       Impact factor: 3.573

5.  Cleaning ability and induced dentin loss of a magnetostrictive ultrasonic instrument at different power settings.

Authors:  Kathrin Lampe Bless; Beatrice Sener; Jürg Dual; Thomas Attin; Patrick R Schmidlin
Journal:  Clin Oral Investig       Date:  2010-02-03       Impact factor: 3.573

6.  The effectiveness of an actuator-driven pulsed water jet for the removal of artificial dental calculus: a preliminary study.

Authors:  Yuka Sato; Masahiro Iikubo; Takashi Nishioka; Nobuhiro Yoda; Tetsuya Kusunoki; Atsuhiro Nakagawa; Keiichi Sasaki; Teiji Tominaga
Journal:  BMC Oral Health       Date:  2020-07-13       Impact factor: 2.757

7.  Efficacy of a new Activation Device in Irrigant Penetration Into Simulated Lateral Canals.

Authors:  Carlos Vieira Andrade-Junior; Rafaela M Batista; Marilia Marceliano-Alves; Flávio Rodrigues Ferreira Alves; Emmanuel João Nogueira Leal Silva
Journal:  Eur Endod J       Date:  2016-09-29

8.  Influence of scaler tip design on root surface roughness, tooth substance loss and patients' pain perception: an in vitro and a randomised clinical trial.

Authors:  Nur Ayman Abdul Hayei; Noor Azlin Yahya; Syarida Hasnur Safii; Roslan Saub; Rathna Devi Vaithilingam; Nor Adinar Baharuddin
Journal:  BMC Oral Health       Date:  2021-03-31       Impact factor: 2.757

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.