Literature DB >> 19328278

In vitro comparison of the cutting efficiency and temperature production of 10 different rotary cutting instruments. Part I: Turbine.

Carlo Ercoli1, Mario Rotella, Paul D Funkenbusch, Scott Russell, Changyong Feng.   

Abstract

STATEMENT OF PROBLEM: Standards to test the cutting efficiency of dental rotary cutting instruments are either nonexistent or inappropriate, and knowledge of the factors that affect their cutting performance is limited. Therefore, rotary cutting instruments for crown preparation are generally marketed with weak or unsupported claims of superior performance.
PURPOSE: The purpose of this study was to examine the cutting behavior of a wide selection of rotary cutting instruments under carefully controlled and reproducible conditions with an air-turbine handpiece.
MATERIAL AND METHODS: Ten groups of rotary cutting instruments (n=30) designed for tooth preparation were selected: 9 diamond rotary cutting instruments (7 multi-use, 2 disposable) and 1 carbide bur. One bur per group was imaged with a scanning electron microscope (SEM) at different magnifications. Macor blocks (n=75) were used as a substrate, and 4 cuts were made on each specimen, using a new rotary cutting instrument each time, for a total of 300 cuts. The cuts were performed with an air-turbine handpiece (Midwest Quiet Air). A computer-controlled, custom-made testing apparatus was used to monitor all sensors and control the cutting action. The data were analyzed to compare the correlation of rotary cutting instrument type, grit, amount of pressure, cutting rate, revolutions per minute (rpm), temperature, and type of handpiece, using 1-way ANOVA and Tukey's Studentized Range test (alpha=.05).
RESULTS: Compared to the baseline temperature, all rotary cutting instruments showed a reduction of temperature in the simulated pulp chamber. The Great White Ultra (carbide bur) showed a significantly higher rate of advancement (0.15 mm/s) and lower applied load (106.46 g) and rpm (304,375.97).
CONCLUSIONS: Tooth preparation with an adequate water flow does not cause harmful temperature changes in the pulp chamber, regardless of rotary cutting instrument type. The tested carbide bur showed greater cutting efficiency than all diamond rotary cutting instruments.

Entities:  

Mesh:

Year:  2009        PMID: 19328278     DOI: 10.1016/S0022-3913(09)60049-4

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

Review 1.  Tooth preparation for full-coverage restorations-a literature review.

Authors:  Anke Podhorsky; Peter Rehmann; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

2.  Temperature rise on the external root surface during removal of endodontic fractured instruments.

Authors:  A A Madarati; D C Watts
Journal:  Clin Oral Investig       Date:  2013-08-08       Impact factor: 3.573

3.  Influence of microwave sterilization on the cutting capacity of carbide burs.

Authors:  Laiza Maria Grassi Fais; Lígia Antunes Pereira Pinelli; Gelson Luis Adabo; Regina Helena Barbosa Tavares da Silva; Caroline Canhizares Marcelo; Dalton Geraldo Guaglianoni
Journal:  J Appl Oral Sci       Date:  2009 Nov-Dec       Impact factor: 2.698

4.  Effect of simulated chairside grinding procedures using commercially available abrasive agents on the surface properties of zirconia.

Authors:  Ramandeep Sandhu; Mohit Kheur; Supriya Kheur
Journal:  J Indian Prosthodont Soc       Date:  2017 Jan-Mar

5.  The cooling efficiency of different dental high-speed handpiece coolant port designs.

Authors:  Helene Chua; Joanne Jung Eun Choi; Rishi Sanjay Ramani; Ritu Ganjigatti; John Neil Waddell
Journal:  Heliyon       Date:  2019-08-26

6.  Cutting Efficiency of Welded Diamond and Vacuum Diffusion Technology Burs and Conventional Electroplated Burs on the Surface Changes of the Teeth - An In vitro Study.

Authors:  Tanya Kabir Sethi; Ramesh P Nayakar; Anandkumar G Patil
Journal:  Contemp Clin Dent       Date:  2021-09-21

7.  What is the changing frequency of diamond burs?

Authors:  Faruk Emir; Simel Ayyildiz; Cem Sahin
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

8.  Effect of cooling water temperature on the temperature changes in pulp chamber and at handpiece head during high-speed tooth preparation.

Authors:  Ra'fat I Farah
Journal:  Restor Dent Endod       Date:  2018-12-24

9.  A Comparative Study on Simulated Chairside Grinding and Polishing of Monolithic Zirconia.

Authors:  Mohit Kheur; Tabrez Lakha; Saleha Shaikh; Supriya Kheur; Batul Qamri; Lee Wan Zhen; Nadin Al-Haj Husain; Mutlu Özcan
Journal:  Materials (Basel)       Date:  2022-03-16       Impact factor: 3.623

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.