Literature DB >> 19328039

ICD lead proarrhythmia cured by lead extraction.

Joseph C Lee1, Laurence M Epstein, Linda L Huffer, William G Stevenson, Bruce A Koplan, Usha B Tedrow.   

Abstract

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) reduce mortality in patients at risk for sudden cardiac death. However, clinical trials report higher rates of appropriate ICD therapies in implanted patients than untreated patient mortality rates would predict.
OBJECTIVE: This study sought to describe a newly recognized form of ventricular proarrhythmia related to the mechanical presence of the ICD.
METHODS: Four ICD patients were referred for management of recurrent ventricular tachycardia (VT) refractory to medications and catheter ablation. All were treated with lead extraction and followed prospectively for arrhythmia recurrence.
RESULTS: Two patients received ICDs for primary prevention because of a family history of sudden death and nonischemic cardiomyopathy, respectively. Episodes of VT with ICD therapies began 2 months and 1 year after implantation, and continued for 3 months and 5 years, respectively, until referral. Two secondary prevention ICD patients with ischemic cardiomyopathy developed incessant VT within 1 day and 3 days after implantation with multiple ICD shocks. VT was not suppressed by antiarrhythmic drugs, and catheter ablation failed in 2 patients. In all patients, spontaneous VT's had a QRS morphology similar to the paced morphology from the ICD leads, raising suspicion of lead-related proarrhythmia. After lead extraction, primary prevention ICD patients remained free of VT during follow-up periods of 17 and 21 months, and VT storm was controlled in the secondary prevention patients.
CONCLUSIONS: ICD leads can cause uncontrollable VT until the lead is extracted, suggesting a mechanical effect. In contrast to transient ectopy that occurs early after implantation, this proarrhythmia can be chronic. Recognition is important because lead extraction is curative and can prevent unnecessary ICD shocks, antiarrhythmic medications, and catheter ablation.

Entities:  

Mesh:

Year:  2009        PMID: 19328039     DOI: 10.1016/j.hrthm.2009.01.039

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  9 in total

1.  Incessant ventricular tachycardia, refractory to catheter ablation, in an ICD patient terminated by ICD lead extraction: a case report.

Authors:  Corinna Lenz; Thomas Dietze; Michael Möller; Wolfgang Schöbel; Jens Wicke; Hans-Jörg Kellner; Rainer Gradaus; Jörg Neuzner
Journal:  Clin Res Cardiol       Date:  2009-08-28       Impact factor: 5.460

Review 2.  The importance of non-uniformities in mechano-electric coupling for ventricular arrhythmias.

Authors:  T Alexander Quinn
Journal:  J Interv Card Electrophysiol       Date:  2013-12-12       Impact factor: 1.900

3.  An Uncommon Ventricular Tachycardia due to Inactive PPM Lead.

Authors:  Goutam Datta; A Sarkar; A Haque
Journal:  ISRN Cardiol       Date:  2011-04-14

4.  First direct human evidence of a probable implantable cardioverter-defibrillator lead-related scar serving as a substrate for ventricular tachycardia.

Authors:  Pal Abraham; Kadir Caliskan; Joanne Verheij; Tamas Szili-Torok
Journal:  HeartRhythm Case Rep       Date:  2015-01-02

5.  Mechanically Induced Ectopy via Stretch-Activated Cation-Nonselective Channels Is Caused by Local Tissue Deformation and Results in Ventricular Fibrillation if Triggered on the Repolarization Wave Edge (Commotio Cordis).

Authors:  T Alexander Quinn; Honghua Jin; Peter Lee; Peter Kohl
Journal:  Circ Arrhythm Electrophysiol       Date:  2017-08

6.  Ventricular tachycardia secondary to abandoned epicardial pacemaker lead.

Authors:  Chance M Witt; Samuel J Asirvatham; Carole A Warnes; Christopher J McLeod
Journal:  HeartRhythm Case Rep       Date:  2015-02-12

7.  Right ventricular lead proarrhythmia: A novel intervention for an under-recognized phenomenon.

Authors:  Justin Hayase; Houman Khakpour; Kalyanam Shivkumar; Jason S Bradfield
Journal:  HeartRhythm Case Rep       Date:  2017-12-12

8.  Implantable defibrillator lead extraction with optimized standard extraction techniques.

Authors:  Xian-Ming Chu; Xue-Bin Li; Ping Zhang; Yi An; Jiang-Bo Duan; Long Wang; Ding Li; Bing Li; Ji-Hong Guo
Journal:  J Geriatr Cardiol       Date:  2013-03       Impact factor: 3.327

Review 9.  Rabbit models of cardiac mechano-electric and mechano-mechanical coupling.

Authors:  T Alexander Quinn; Peter Kohl
Journal:  Prog Biophys Mol Biol       Date:  2016-05-18       Impact factor: 3.667

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.