Abstract
Field measurements were conducted to assess the effects of an air cleaner on radon mitigation in a dwelling with a high radon concentration in Okinawa, Japan. The measurements included indoor radon concentration, individual radon progeny concentration, equilibrium equivalent concentration of radon (EECRn), unattached fraction, and size distribution of aerosol-attached radon progeny. These measurements were conducted in a 74 m(3) room with/without the use of an air cleaner. The results showed that the mean radon concentration during the measurement was quite high (301 Bq m(-3)). The operation of air cleaner decreased the radon progeny activity concentration, EECRn and equilibrium factor by 33%, 57% and 71%, respectively, whereas the unattached fraction increased by 174%. In addition, the activity concentration of attached radon progeny in the accumulation mode (50-2000 nm) was obviously deceased by 42%, when the air cleaner was operated. According to dosimetric calculations, the operation of air cleaner reduced the effective dose due to radon progeny by about 50%.Mesh:
Substances:
Year: 2009 PMID: 19328003 DOI: 10.1016/j.apradiso.2009.02.087
Source DB: PubMed Journal: Appl Radiat Isot ISSN: 0969-8043 Impact factor: 1.513