Literature DB >> 19324951

Evaluating noninvasive ventilation using a monitoring system coupled to a ventilator: a bench-to-bedside study.

C Rabec1, M Georges, N K Kabeya, N Baudouin, F Massin, O Reybet-Degat, P Camus.   

Abstract

Empirically determined noninvasive ventilation (NIV) settings may not achieve optimal ventilatory support. Some ventilators include monitoring modules to assess ventilatory quality. We conducted a bench-to-bedside study to assess the ventilatory quality of the VPAPIII-ResLink (ResMed, North Ryde, Australia). We tested the accuracy of minute ventilation (MV) and leak calculations given by VPAPIII-ResLink compared to those measured by a bench model at varied leak levels and ventilator settings. We systematically assessed NIV efficacy using this system from 2003 to 2006. Ventilation was considered inadequate if leak (>24 L x min(-1)), continuous desaturation (>30% of the trace) or desaturation dips (>3%) were present. On the bench test, both methods were highly correlated (r = 0.947, p>0.0001 and r = 0.959, p<0.0001 for leak and MV, respectively). We performed 222 assessments in 169 patients (aged 66.42+/-16 yrs, 100 males). Abnormalities were detected on 147 (66%) out of 222 occasions. Leak was the most common abnormality (34.2%) followed by desaturation dips (23.8%). The most effective therapeutic solutions were a chin strap if leak was detected (61.2%) and expiratory positive airway pressure increase for desaturation dips (59.5%). In 15.7% of cases, when abnormalities persisted, a polygraphy was performed. The systematic use of this device enables NIV to be optimised, limiting the indication of sleep studies to complex cases.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19324951     DOI: 10.1183/09031936.00170508

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  12 in total

1.  Are home ventilators able to guarantee a minimal tidal volume?

Authors:  Brigitte Fauroux; Karl Leroux; Jean-Louis Pépin; Frédéric Lofaso; Bruno Louis
Journal:  Intensive Care Med       Date:  2010-03-09       Impact factor: 17.440

Review 2.  Basic Concepts for Tidal Volume and Leakage Estimation in Non-Invasive Ventilation.

Authors:  Manel Luján; Cristina Lalmolda; Begüm Ergan
Journal:  Turk Thorac J       Date:  2019-04-01

3.  And the Doctor Answers: "Dream, Dream, I Will Be the Guardian of Your Breathing…".

Authors:  Claudio Rabec; Jésus Gonzalez-Bermejo; Christophe Perrin; Bruno Langevin; Jean-Louis Pepin; Daniel Rodenstein; Jean Paul Janssens
Journal:  J Clin Sleep Med       Date:  2016-08-15       Impact factor: 4.062

4.  Patients' preferences and the efficacy of a hybrid model of a minimal contact nasal mask in patients with sleep apnea treated with CPAP.

Authors:  Magali Blanco; Veronica Jaritos; Glenda Ernst; Alejandro Salvado; Facundo Nogueira; Eduardo Borsini
Journal:  Sleep Sci       Date:  2018 Jul-Aug

5.  Polygraphic respiratory events during sleep with noninvasive ventilation in children: description, prevalence, and clinical consequences.

Authors:  Valeria Caldarelli; Jean Christian Borel; Sonia Khirani; Adriana Ramirez; Renato Cutrera; Jean-Louis Pépin; Brigitte Fauroux
Journal:  Intensive Care Med       Date:  2013-01-24       Impact factor: 17.440

6.  Polysomnography in stable COPD under non-invasive ventilation to reduce patient-ventilator asynchrony and morning breathlessness.

Authors:  Dan Adler; Stephen Perrig; Hiromitsu Takahashi; Fabrice Espa; Daniel Rodenstein; Jean Louis Pépin; Jean-Paul Janssens
Journal:  Sleep Breath       Date:  2011-11-04       Impact factor: 2.816

7.  Home noninvasive positive pressure ventilation with built-in software in stable hypercapnic COPD: a short-term prospective, multicenter, randomized, controlled trial.

Authors:  Luqian Zhou; Xiaoying Li; Lili Guan; Jianhua Chen; Bingpeng Guo; Weiliang Wu; Yating Huo; Ziqing Zhou; Zhenyu Liang; Yuqi Zhou; Jie Tan; Xin Chen; Yuanlin Song; Rongchang Chen
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2017-04-27

8.  Using domiciliary non-invasive ventilator data downloads to inform clinical decision-making to optimise ventilation delivery and patient compliance.

Authors:  Stephanie K Mansell; Steven Cutts; Isobel Hackney; Martin J Wood; Kevin Hawksworth; Dean D Creer; Cherry Kilbride; Swapna Mandal
Journal:  BMJ Open Respir Res       Date:  2018-03-03

9.  Effect of dynamic random leaks on the monitoring accuracy of home mechanical ventilators: a bench study.

Authors:  Ana Sogo; Jaume Montanyà; Eduard Monsó; Lluís Blanch; Xavier Pomares; Manel Lujàn
Journal:  BMC Pulm Med       Date:  2013-12-10       Impact factor: 3.317

10.  Respiratory polygraphy monitoring of intensive care patients receiving non-invasive ventilation.

Authors:  Eduardo Borsini; Glenda Ernst; Magalí Blanco; Miguel Blasco; Martín Bosio; Alejandro Salvado; Carlos Nigro
Journal:  Sleep Sci       Date:  2017 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.