| Literature DB >> 19324544 |
Yayi Wang1, Yongzhen Peng, Tom Stephenson.
Abstract
A laboratory-scale anaerobic-anoxic/nitrification sequencing batch reactor (A(2)N-SBR) fed with domestic wastewater was operated to examine the effect of varying ratios of influent COD/P, COD/TN and TN/P on the nutrient removal. With the increased COD/P, the phosphorus removals exhibited an upward trend. The influent TN/P ratios had a positive linear correlation with the phosphorus removal efficiencies, mainly because nitrates act as electron acceptors for the phosphorus uptake in the A(2)N-SBR. Moreover, it was found that lower COD/TN ratio, e.g. 3.5, did not significantly weaken the phosphorus removal, though the nitrogen removal first decreased greatly. The optimal phosphorus and nitrogen removals of 94% and 91%, respectively were achieved with influent COD/P and COD/TN ratios of 19.9 and 9.9, respectively. Additionally, a real-time control strategy for A(2)N-SBR can be undertaken based on some characteristic points of pH, redox potential (ORP) and dissolved oxygen (DO) profiles in order to obtain the optimum hydraulic retention time (HRT) and improve the operating reliability.Entities:
Mesh:
Substances:
Year: 2009 PMID: 19324544 DOI: 10.1016/j.biortech.2009.02.026
Source DB: PubMed Journal: Bioresour Technol ISSN: 0960-8524 Impact factor: 9.642