Development of in vivo measuring system of the pressure distribution under the denture base of removable partial denture.

Kei Kubo1, Tetsuo Kawata, Hanako Suenaga, Nobuhiro Yoda, Ryuji Shigemitsu, Toru Ogawa, Keiichi Sasaki.   

Abstract

PURPOSE: To develop a system to measure the pressure distribution under the base of a removable partial denture (RPD) and to apply it in vivo.
METHODS: A tactile sensor sheet with 100 sensing points and a measuring system (I-SCAN, Nitta, Osaka, Japan) were used. The sensor was calibrated before being applied in vivo. A subject with a mandibular RPD (Kennedy class II, division 1) participated in this study, and the RPD was duplicated as the experimental denture. The basal surface at distal extension was accommodated to the sensor in a manner similar to direct relining. Measurements were performed with three patterns of occlusal rest design (mesial and distal rests, mesial rest only, and without a rest) during maximal voluntary clenching (MVC) and gum chewing.
RESULTS: The calibration measurements showed that the output value from each sensing point and total output of sensing points were positively correlated with the applied load. The pressures recorded in vivo varied depending on the locations of sensing points on the basal surface of the denture. During MVC the pressure distribution changed with the clenching level, and the highest pressure was registered near the residual ridge crest. The pressure distribution also changed according to the number of occlusal rests. The load center shifted about 2mm during MVC and about 4mm during gum chewing.
CONCLUSION: The measuring system developed here enabled us to measure the pressure distribution under the denture base of RPD. The pressure distribution varied along with the design of the occlusal rest.

Mesh:

Year:  2008        PMID: 19318066     DOI: 10.1016/j.jpor.2008.08.006

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  4 in total

1.  Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures.

Authors:  Nobuhiro Yoda; Yoshiki Matsudate; Masaru Abue; Guang Hong; Keiichi Sasaki
Journal:  J Dent Biomech       Date:  2015-03-16

Review 2.  Biomechanical factors related to occlusal load transfer in removable complete dentures.

Authors:  Jarosław Żmudzki; Grzegorz Chladek; Jacek Kasperski
Journal:  Biomech Model Mechanobiol       Date:  2014-12-20

3.  Shape Optimization for Additive Manufacturing of Removable Partial Dentures--A New Paradigm for Prosthetic CAD/CAM.

Authors:  Junning Chen; Rohana Ahmad; Hanako Suenaga; Wei Li; Keiichi Sasaki; Michael Swain; Qing Li
Journal:  PLoS One       Date:  2015-07-10       Impact factor: 3.240

Review 4.  Biomechanics of oral mucosa.

Authors:  Junning Chen; Rohana Ahmad; Wei Li; Michael Swain; Qing Li
Journal:  J R Soc Interface       Date:  2015-08-06       Impact factor: 4.118

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.