Literature DB >> 19307128

A comparison of dose distributions of HDR intracavitary brachytherapy using different sources and treatment planning systems.

Dong-wook Park1, Young Seok Kim, Sung Ho Park, Eun Kyung Choi, Seung Do Ahn, Sang-wook Lee, Si Yeol Song, Jong Hoon Kim.   

Abstract

To evaluate the influence of different sources and treatment planning systems (TPSs), we calculated the dose distributions of 10 patients treated by HDR intracavitary brachytherapy. The dose distributions of treatment plans were compared to the points A, B and ICRU bladder and rectum reference points located in the relevant clinical planes. The results show that the dose discrepancies between the two treatment plans are mainly affected by the differences in the physical characteristics of source and the positioning method in TPSs.

Entities:  

Mesh:

Year:  2009        PMID: 19307128     DOI: 10.1016/j.apradiso.2009.02.066

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  8 in total

1.  Study of the dosimetric differences between (192)Ir and (60)Co sources of high dose rate brachytherapy for breast interstitial implant.

Authors:  Mourougan Sinnatamby; Vivekanandan Nagarajan; Reddy Kanipakam Sathyanarayana; Gunaseelan Karunanidhi; Vivekanandam Singhavajala
Journal:  Rep Pract Oncol Radiother       Date:  2016-05-11

2.  Intra-cavitary brachytherapy in endometrial carcinoma: experience with cobalt-60 source.

Authors:  Jose Antonio Domínguez Rullán; María Teresa Muñoz Miguelañez; Rafael Colmenares Fernández; Miguel Cámara Gallego; Mercedes Martín Sánchez; Feliciano García Vicente; Sonsoles Sancho García
Journal:  J Contemp Brachytherapy       Date:  2022-05-10

Review 3.  Comparative Analysis of 60Co and 192Ir Sources in High Dose Rate Brachytherapy for Cervical Cancer.

Authors:  Aiping Wen; Xianliang Wang; Bingjie Wang; Chuanjun Yan; Jingyue Luo; Pei Wang; Jie Li
Journal:  Cancers (Basel)       Date:  2022-09-29       Impact factor: 6.575

4.  Treatment planning study of the 3D dosimetric differences between Co-60 and Ir-192 sources in high dose rate (HDR) brachytherapy for cervix cancer.

Authors:  Antony Palmer; Orla Hayman; Sarah Muscat
Journal:  J Contemp Brachytherapy       Date:  2012-03-30

5.  Comparison of (60)Co and (192)Ir sources in HDR brachytherapy.

Authors:  Stefan Strohmaier; Grzegorz Zwierzchowski
Journal:  J Contemp Brachytherapy       Date:  2011-12-30

6.  A comparative assessment of inhomogeneity and finite patient dimension effects in 60Co and 192Ir high-dose-rate brachytherapy.

Authors:  Irina Fotina; Kyveli Zourari; Vasileios Lahanas; Evaggelos Pantelis; Panagiotis Papagiannis
Journal:  J Contemp Brachytherapy       Date:  2018-02-28

7.  Treatment outcomes of high-dose-rate intracavitary brachytherapy for cervical cancer: a comparison of Ir-192 versus Co-60 sources.

Authors:  Thanatip Tantivatana; Kanisa Rongsriyam
Journal:  J Gynecol Oncol       Date:  2018-09       Impact factor: 4.401

Review 8.  High dose rate versus low dose rate intracavity brachytherapy for locally advanced uterine cervix cancer.

Authors:  Ruifeng Liu; XiaoHu Wang; Jin Hui Tian; KeHu Yang; Jun Wang; Lei Jiang; Xiang Yong Hao
Journal:  Cochrane Database Syst Rev       Date:  2014-10-09