PURPOSE: To detect differences in magnetic resonance imaging (MRI) between chondroblastic osteosarcoma and the other types of osteosarcomas or chondrosarcomas using gadolinium-enhanced versus diffusion-weighted sequences. MATERIALS AND METHODS: Contrast-enhanced MRI and diffusion-weighted imaging (DWI) were performed in five chondroblastic osteosarcoma (CO) cases, 17 other types of osteosarcomas (OS), and 18 chondrosarcomas (CS). DWI was obtained with a single-shot echo-planar imaging (EPI) sequence using a 1.5 T MR imager. The apparent diffusion coefficients (ADCs) of the minimum and maximum values were also obtained. The contrast-enhancement pattern was evaluated and minimum-maximum ADC value of CO was compared with other types of OS and CS. RESULTS: Both CO and CS showed a similar enhancement pattern; both showed septonodular and peripheral rim enhancement. The minimum ADC value of CO (1.24 +/- 0.10 x 10(-3)mm(2)/sec) was significantly higher than that of other types of OS (0.84 +/- 0.15 x 10(-3)mm(2)/sec) and was significantly lower than that of CS (1.64 +/- 0.20 x 10(-3)mm(2)/sec). In addition, the maximum ADC value of CO (2.28 +/- 0.20 x 10(-3)mm(2)/sec) was significantly higher than that of other types of OS (1.33 +/- 0.26 x 10(-3)mm(2)/sec). CONCLUSION: DWI appears to be more useful for differentiating between chondroblastic osteosarcoma and chondrosarcoma or other types of osteosarcoma than Gd-enhanced MRI.
PURPOSE: To detect differences in magnetic resonance imaging (MRI) between chondroblastic osteosarcoma and the other types of osteosarcomas or chondrosarcomas using gadolinium-enhanced versus diffusion-weighted sequences. MATERIALS AND METHODS: Contrast-enhanced MRI and diffusion-weighted imaging (DWI) were performed in five chondroblastic osteosarcoma (CO) cases, 17 other types of osteosarcomas (OS), and 18 chondrosarcomas (CS). DWI was obtained with a single-shot echo-planar imaging (EPI) sequence using a 1.5 T MR imager. The apparent diffusion coefficients (ADCs) of the minimum and maximum values were also obtained. The contrast-enhancement pattern was evaluated and minimum-maximum ADC value of CO was compared with other types of OS and CS. RESULTS: Both CO and CS showed a similar enhancement pattern; both showed septonodular and peripheral rim enhancement. The minimum ADC value of CO (1.24 +/- 0.10 x 10(-3)mm(2)/sec) was significantly higher than that of other types of OS (0.84 +/- 0.15 x 10(-3)mm(2)/sec) and was significantly lower than that of CS (1.64 +/- 0.20 x 10(-3)mm(2)/sec). In addition, the maximum ADC value of CO (2.28 +/- 0.20 x 10(-3)mm(2)/sec) was significantly higher than that of other types of OS (1.33 +/- 0.26 x 10(-3)mm(2)/sec). CONCLUSION: DWI appears to be more useful for differentiating between chondroblastic osteosarcoma and chondrosarcoma or other types of osteosarcoma than Gd-enhanced MRI.
Authors: Nicholas Bhojwani; Peter Szpakowski; Sasan Partovi; Martin H Maurer; Ulrich Grosse; Hendrik von Tengg-Kobligk; Lisa Zipp-Partovi; Nathan Fergus; Christos Kosmas; Konstantin Nikolaou; Mark R Robbin Journal: Quant Imaging Med Surg Date: 2015-10