Literature DB >> 19304097

Effect of hydrodynamic parameters on corneal endothelial cell loss after phacoemulsification.

Alireza Baradaran-Rafii1, Mohsen Rahmati-Kamel, Medi Eslani, Victoria Kiavash, Farid Karimian.   

Abstract

PURPOSE: To evaluate the effect of power, vacuum, and flow rate on endothelial cell loss after phacoemulsification.
SETTING: Labbafinejad Medical Center Medical Center, Tehran, Iran.
METHODS: In a prospective randomized clinical trial, phacoemulsification was performed in 2 groups (high vacuum and low vacuum) with 3+ nuclear sclerosis. The stop-and-chop technique was used with the Sovereign machine. Machine parameters during the chop stage were vacuum 400 mm Hg in the high-vacuum group and 200 mm Hg in the low-vacuum group and flow rate, 40 cc/min and 20 cc/min, respectively. Endothelial cell density preoperatively before and 1, 6, and 12 weeks postoperatively were compared.
RESULTS: Each group comprised 30 eyes. The mean US power was 9.2% +/- 4.3% (SD) in the low-vacuum group and 13.1% +/- 4.6% in the high-vacuum group (P = .001) and the mean phaco time, 1.28 +/- 1.0 minutes and 0.88 +/- 0.6 minutes, respectively (P = .04). Total US energy and total fluid consumed were similar between groups. After 12 weeks, the mean endothelial cell loss was 9.0% +/- 4.0% in the low-vacuum group and 9.6% +/- 4.6% in the high-vacuum group (P = .6). There was a relationship between total US energy and endothelial loss (P<.001); however, total fluid volume was not a significant predictor (P = .19).
CONCLUSIONS: Vacuum level did not have a significant effect on total US energy or total fluid consumed during phacoemulsification. There was a strong relationship between total US energy and endothelial cell loss but not between total infused fluid and endothelial cell loss.

Entities:  

Mesh:

Year:  2009        PMID: 19304097     DOI: 10.1016/j.jcrs.2008.12.017

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  13 in total

1.  Influence of anterior chamber depth, anterior chamber volume, axial length, and lens density on postoperative endothelial cell loss.

Authors:  Anna Reuschel; Holger Bogatsch; Nicole Oertel; Renate Wiedemann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-03-01       Impact factor: 3.117

2.  Comparison of cornea endothelial cell counts after combined phacovitrectomy versus pars plana vitrectomy with fragmentation.

Authors:  Youngsub Eom; Seong-Woo Kim; Jaemoon Ahn; Jee Taek Kim; Kuhl Huh
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-08-15       Impact factor: 3.117

3.  Optical coherence tomography angiography evaluation of the effects of phacoemulsification cataract surgery on macular hemodynamics in Chinese normal eyes.

Authors:  Xinyu Jia; Yinjuan Wei; Hui Song
Journal:  Int Ophthalmol       Date:  2021-08-04       Impact factor: 2.031

4.  Corneal endothelial morphology and function after torsional and longitudinal ultrasound mode phacoemulsification.

Authors:  László Jr Módis; Eszter Szalai; Zsuzsa Flaskó; Gábor Németh
Journal:  Rom J Ophthalmol       Date:  2016 Apr-Jun

5.  New ex vivo model of corneal endothelial phacoemulsification injury and rescue therapy with mesenchymal stromal cell secretome.

Authors:  Majid Rouhbakhshzaeri; Behnam Rabiee; Nathalie Azar; Elham Ghahari; Ilham Putra; Medi Eslani; Ali R Djalilian
Journal:  J Cataract Refract Surg       Date:  2018-12-07       Impact factor: 3.351

6.  A Rabbit Model Study to Determine the Efficacy of a Prototype Corneal Endothelium Protector during Cataract Surgery.

Authors:  Annabel C Y Chew; Anita Chan; Monisha E Nongpiur; Gary Peh; Veluchamy A Barathi; Nyein C Lwin; Charles Ong; Shamira Perera
Journal:  J Ophthalmol       Date:  2017-03-29       Impact factor: 1.909

7.  Phacoemulsification in the anterior chamber: An alternative surgical technique in post-vitrectomy cataract.

Authors:  Tao Yu; Xu-Guang Han; Ying-Mei Li; Yu-Guang Zhang
Journal:  Pak J Med Sci       Date:  2018 Nov-Dec       Impact factor: 1.088

8.  Effect of fluidics on corneal endothelial cell density, central corneal thickness, and central macular thickness after phacoemulsification with torsional ultrasound.

Authors:  Sudeep Das; Soumya Ganesh Nanaiah; Mathew K Kummelil; Somshekar Nagappa; Rohit Shetty; Bhujang K Shetty
Journal:  Indian J Ophthalmol       Date:  2015-08       Impact factor: 1.848

9.  Intra-correlations between cataract density based on Scheimpflug image, phacodynamics, surgery duration, and endothelial cell loss after phacoemulsification.

Authors:  Abdullah M Al-Osaily; Mohanna Y Al-Jindan
Journal:  Saudi J Ophthalmol       Date:  2018-04-10

10.  Prospective randomized comparative study between venturi and peristaltic pumps in WhiteStar Signature® phacoemulsification machine.

Authors:  Wilson Takashi Hida; André Lins de Medeiros; André Gustavo de Araújo Rolim; Antonio Francisco Pimenta Motta; Danilo Varela Kniggendorf; Rodrigo Lafetá Franco de Queiroz; Mário Augusto Pereira Dias Chaves; Pedro Carlos Carricondo; Celso Takashi Nakano; Walton Nosé
Journal:  Clin Ophthalmol       Date:  2018-12-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.