Literature DB >> 19303128

Assessment of annual pollutant loads in combined sewers from continuous turbidity measurements: sensitivity to calibration data.

C Lacour1, C Joannis, G Chebbo.   

Abstract

This article presents a methodology for assessing annual wet weather Suspended Solids (SS) and Chemical Oxygen Demand (COD) loads in combined sewers, along with the associated uncertainties from continuous turbidity measurements. The proposed method is applied to data from various urban catchments in the cities of Paris and Nantes. The focus here concerns the impact of the number of rain events sampled for calibration (i.e. through establishing linear SS/turbidity or COD/turbidity relationships) on the uncertainty of annual pollutant load assessments. Two calculation methods are investigated, both of which rely on Monte Carlo simulations: random assignment of event-specific calibration relationships to each individual rain event, and the use of an overall relationship built from the entire available data set. Since results indicate a fairly low inter-event variability for calibration relationship parameters, an accurate assessment of pollutant loads can be derived, even when fewer than 10 events are sampled for calibration purposes. For operational applications, these results suggest that turbidity could provide a more precise evaluation of pollutant loads at lower cost than typical sampling methods.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19303128     DOI: 10.1016/j.watres.2009.02.017

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  3 in total

1.  Stochastic evaluation of annual micropollutant loads and their uncertainties in separate storm sewers.

Authors:  Ali Hannouche; Ghassan Chebbo; Claude Joannis; Johnny Gasperi; Marie-Christine Gromaire; Régis Moilleron; Sylvie Barraud; Véronique Ruban
Journal:  Environ Sci Pollut Res Int       Date:  2017-10-11       Impact factor: 4.223

2.  Assessment of pollutant load emission from combined sewer overflows based on the online monitoring.

Authors:  Agnieszka Brzezińska; Marek Zawilski; Grażyna Sakson
Journal:  Environ Monit Assess       Date:  2016-08-03       Impact factor: 2.513

3.  Determining suspended solids and total phosphorus from turbidity: comparison of high-frequency sampling with conventional monitoring methods.

Authors:  Ana Villa; Jens Fölster; Katarina Kyllmar
Journal:  Environ Monit Assess       Date:  2019-09-04       Impact factor: 2.513

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.