Literature DB >> 19302647

Optimising tracheal intubation success rate using the Airtraq laryngoscope.

G Dhonneur1, W Abdi, R Amathieu, S Ndoko, L Tual.   

Abstract

In this study we have used a video-recording, retrospective analysis technique to evaluate the influence of the Airtraq laryngoscope manipulations and the resulting changes in position of the glottic opening and inter-arytenoids cleft, on the success rate of tracheal intubation. The video recordings of the internal views of 109 tracheal intubation attempts, in 50 anaesthetised patients were analysed. We demonstrated that successful tracheal intubation using the Airtraq laryngoscope require the glottic opening to be centred in the view, and positioning the inter-arytenoid cleft medially below the horizontal line in the centre of the view. We also demonstrated that repositioning of the Airtraq laryngoscope following a failed tracheal intubation attempt required the performance of a standard series of manoeuvres.

Entities:  

Mesh:

Year:  2009        PMID: 19302647     DOI: 10.1111/j.1365-2044.2008.05757.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  12 in total

1.  Comments on comparison of the combined Airtraq® laryngoscope and a fiberoptic bronchoscope with the Airtraq® alone for tracheal intubation.

Authors:  Fu Shan Xue; Jian Hua Liu; Yu Jing Yuan; Xu Liao
Journal:  J Anesth       Date:  2011-04-13       Impact factor: 2.078

Review 2.  [Indirect laryngoscopy : Alternatives to securing the airway].

Authors:  R R Noppens; C Werner; T Piepho
Journal:  Anaesthesist       Date:  2010-02       Impact factor: 1.041

3.  Intubation biomechanics: laryngoscope force and cervical spine motion during intubation with Macintosh and Airtraq laryngoscopes.

Authors:  Bradley J Hindman; Brandon G Santoni; Christian M Puttlitz; Robert P From; Michael M Todd
Journal:  Anesthesiology       Date:  2014-08       Impact factor: 7.892

4.  Awake tracheal intubation using combination of an Airtraq® optical laryngoscope with smartphone and video flexible endoscope: a case report.

Authors:  Zhi-Qiang Zhou; Xu Zhao; Hong-Bing Xiang
Journal:  Am J Nucl Med Mol Imaging       Date:  2018-06-05

Review 5.  Evolution of videolaryngoscopy in pediatric population.

Authors:  Anju Gupta; Ridhima Sharma; Nishkarsh Gupta
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2021-04-10

6.  The use of the Airtraq® optical laryngoscope for routine tracheal intubation in high-risk cardio-surgical patients.

Authors:  Gereon Schälte; Ulrike Scheid; Steffen Rex; Mark Coburn; Britta Fiedler; Rolf Rossaint; Norbert Zoremba
Journal:  BMC Res Notes       Date:  2011-10-19

7.  Comparison of tracheal intubation using the Airtraq(®) and Mc Coy laryngoscope in the presence of rigid cervical collar simulating cervical immobilisation for traumatic cervical spine injury.

Authors:  Padmaja Durga; Jasleen Kaur; Syed Younus Ahmed; Geeta Kaniti; Gopinath Ramachandran
Journal:  Indian J Anaesth       Date:  2012-11

Review 8.  A review of video laryngoscopes relevant to the intensive care unit.

Authors:  Dharshi Karalapillai; Jai Darvall; Justin Mandeville; Louise Ellard; Jon Graham; Laurence Weinberg
Journal:  Indian J Crit Care Med       Date:  2014-07

9.  Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study.

Authors:  Pierre-Géraud Claret; Renaud Asencio; Damien Rogier; Claire Roger; Philippe Fournier; Tu-Anh Tran; Mustapha Sebbane; Xavier Bobbia; Jean Emmanuel de La Coussaye
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-03-22       Impact factor: 2.953

10.  An observational study of feasibility of tracheal intubation using Airtraq in pediatric population.

Authors:  Devendra Wasudeo Thakare; Anila Devchand Malde
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2017 Jul-Sep
View more