Literature DB >> 19302503

Indoor thermal factors and symptoms in office workers: findings from the US EPA BASE study.

M J Mendell1, A G Mirer.   

Abstract

UNLABELLED: Some prior research in office buildings has associated higher indoor temperatures even within the recommended thermal comfort range with increased worker symptoms. We reexamined this relationship in data from 95 office buildings in the US Environmental Protection Agency's Building Assessment Survey and Evaluation Study. We investigated relationships between building-related symptoms and thermal metrics constructed from real-time measurements. We estimated odds ratios and 95% confidence intervals in adjusted logistic regression models with general estimating equations, overall and by season. Winter indoor temperatures spanned the recommended winter comfort range; summer temperatures were mostly colder than the recommended summer range. Increasing indoor temperatures, overall, were associated with increases in few symptoms. Higher winter indoor temperatures, however, were associated with increases in all symptoms analyzed. Higher summer temperatures, above 23 degrees C, were associated with decreases in most symptoms. Humidity ratio, a metric of absolute humidity, showed few clear associations. Thus, increased symptoms with higher temperatures within the thermal comfort range were found only in winter. In summer, buildings were overcooled, and only the higher observed temperatures were within the comfort range; these were associated with decreased symptoms. Confirmation of these findings would suggest that thermal management guidelines consider health effects as well as comfort, and that less conditioning of buildings in both winter and summer may have unexpected health benefits. PRACTICAL IMPLICATIONS: In winter, higher temperatures within the thermal comfort range are common in US office buildings and may be associated with increased symptoms. In summer, temperatures below the thermal comfort range are common and may be associated with increased symptoms. Results from this large study thus suggest that in US office buildings, less winter heating (in buildings that are in heating mode) and less summer cooling may reduce acute symptoms while providing substantial energy conservation benefits, with no expected thermal comfort penalty and, in summer, even thermal comfort benefits. If confirmed, this would be welcome news.

Mesh:

Year:  2009        PMID: 19302503     DOI: 10.1111/j.1600-0668.2009.00592.x

Source DB:  PubMed          Journal:  Indoor Air        ISSN: 0905-6947            Impact factor:   5.770


  4 in total

1.  The relationship between indoor and outdoor temperature, apparent temperature, relative humidity, and absolute humidity.

Authors:  J L Nguyen; J Schwartz; D W Dockery
Journal:  Indoor Air       Date:  2013-06-18       Impact factor: 5.770

2.  Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building.

Authors:  Tiffanie Ramos; Sandra Dedesko; Jeffrey A Siegel; Jack A Gilbert; Brent Stephens
Journal:  PLoS One       Date:  2015-03-02       Impact factor: 3.240

3.  Overcooling of offices reveals gender inequity in thermal comfort.

Authors:  Thomas Parkinson; Stefano Schiavon; Richard de Dear; Gail Brager
Journal:  Sci Rep       Date:  2021-12-08       Impact factor: 4.379

4.  Pursuing occupants' health and well-being in building management: Definition of new metrics based on indoor air parameters.

Authors:  Giulia Vergerio; Cristina Becchio
Journal:  Build Environ       Date:  2022-07-31       Impact factor: 7.093

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.