Literature DB >> 19298915

9-month clinical, angiographic, and intravascular ultrasound results of a prospective evaluation of the Axxess self-expanding biolimus A9-eluting stent in coronary bifurcation lesions: the DIVERGE (Drug-Eluting Stent Intervention for Treating Side Branches Effectively) study.

Stefan Verheye1, Pierfrancesco Agostoni, Christophe L Dubois, Joseph Dens, John Ormiston, Stephen Worthley, Brett Trauthen, Takao Hasegawa, Bon-Kwon Koo, Peter J Fitzgerald, Roxana Mehran, Alexandra J Lansky.   

Abstract

OBJECTIVES: This study sought to assess the safety and performance of the Axxess (Devax Inc., Lake Forest, California) self-expanding drug-eluting stent in coronary bifurcation lesions.
BACKGROUND: Percutaneous treatment of coronary bifurcations is a predictor of adverse late outcomes, in part because of the lack of dedicated devices.
METHODS: Patients with de novo bifurcation lesions were prospectively enrolled in a multicenter study. The Axxess stent was deployed at the level of the carina followed by additional sirolimus-eluting stents in the distal parent vessel (PV) and/or side branch (SB). All patients underwent clinical follow-up at 9 months; 150 were to receive control angiography and 76 were to receive intravascular ultrasound. The primary end point was the rate of major adverse cardiac events (MACE): a composite of death, myocardial infarction (MI), and target lesion revascularization (TLR). Secondary end points included in-segment restenosis, late loss, and percent neointimal volume obstruction.
RESULTS: Overall, 302 patients were treated with 299 Axxess stents (99%). Additional stenting of 1 branch was performed in 21.7% of patients (17.7% PV, 4% SB), and of both branches in 64.7%. At 9 months, 99.3% of patients returned for clinical follow-up; from the angiographic and IVUS substudies, 93.3% and 89.4% returned. The cumulative 9-month MACE rate was 7.7% (0.7% death, 3.3% non-Q-wave MI, 1.0% Q-wave MI, 4.3% TLR). Subacute and late stent thrombosis occurred in 0.7% and 0.3% of patients. Total restenosis was 6.4% (3.6% PV, 4.3% SB), late loss was 0.20 +/- 0.41 mm in the PV and 0.17 +/- 0.34 mm in the SB. In the Axxess stent segment, percent neointimal volume obstruction was 4.3 +/- 5.2%.
CONCLUSIONS: This prospective multicenter study confirms the safety and performance of the Axxess stent in bifurcation lesions. (Drug-Eluting Stent Intervention for Treating Side Branches Effectively; ACTRN12606000259549).

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19298915     DOI: 10.1016/j.jacc.2008.12.012

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  8 in total

1.  The pharmacokinetics of Biolimus A9 after elution from the BioMatrix II stent in patients with coronary artery disease: the Stealth PK Study.

Authors:  Miodrag C Ostojic; Zoran Perisic; Dragan Sagic; Robert Jung; Yan-Ling Zhang; Jamie Bendrick-Peart; Ronald Betts; Uwe Christians
Journal:  Eur J Clin Pharmacol       Date:  2010-10-09       Impact factor: 2.953

Review 2.  Dedicated bifurcation analysis: dedicated devices.

Authors:  Carlos Collet; Ricardo A Costa; Alexandre Abizaid
Journal:  Int J Cardiovasc Imaging       Date:  2011-03-17       Impact factor: 2.357

3.  AXXESS™ Stent: Delivery Indications and Outcomes.

Authors:  John Rawlins; Jehangir Din; Suneel Talwar; Peter O'Kane
Journal:  Interv Cardiol       Date:  2015-05

Review 4.  New concepts in the design of drug-eluting coronary stents.

Authors:  Scot Garg; Christos Bourantas; Patrick W Serruys
Journal:  Nat Rev Cardiol       Date:  2013-02-19       Impact factor: 32.419

Review 5.  Novel drug-eluting stents in the treatment of de novo coronary lesions.

Authors:  Davide Capodanno; Fabio Dipasqua; Corrado Tamburino
Journal:  Vasc Health Risk Manag       Date:  2011-02-25

Review 6.  Revascularization for unprotected left main coronary artery disease: an evolution in clinical decision making.

Authors:  David E Kandzari; John A Ormiston
Journal:  Curr Cardiol Rep       Date:  2011-10       Impact factor: 2.931

7.  New approaches for the assessment of vessel sizes in quantitative (cardio-)vascular X-ray analysis.

Authors:  Johannes P Janssen; Andrei Rares; Joan C Tuinenburg; Gerhard Koning; Alexandra J Lansky; Johan H C Reiber
Journal:  Int J Cardiovasc Imaging       Date:  2009-11-05       Impact factor: 2.357

8.  Drug-eluting coronary stents - focus on improved patient outcomes.

Authors:  Zehra Jaffery; Amit Prasad; John H Lee; Christopher J White
Journal:  Patient Relat Outcome Meas       Date:  2011-09-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.